Seca 780 - Description of faults; Scales cannot be started; Scales show no weight or an incorrect weight (repeatedly); Incomplete digits

Seca 780
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Seca
Sheet
1(2)
Description
of
faults
Please
refer
to
the
operating
instructions
to
ensure
that
the
scales
were
operated
in
the
proper
manner.
In
case
of
a
malfunction,
the
following
table
will
help
you
to
locate
the
fault.
Description
of
the
fault
Possible
cause
Remedy
Scales
cannot
be
started
Battery
is
not
installed
or
discharged
Check
the
batteries
Voltage
supply
is
defective
Check
the
voltage
at
the
appropriate
connections
of
the
electronics;
eliminate
the
interruption
Bus
connection
cable
is
defective
Check
the
plug-in
connections;
check
the
cables
for
interruption
and
replace
them
if
necessary.
Keypad
is
defective
or
not
connected
Check
the
cable
connections;
check
the
cables
and
the
keypad
for
interruption
and
replace
them
if
necessary
Bus
malfunction
Disconnect
the
battery,
wait
for
60
sec.
and
connect
the
battery
again
Scales
show
no
weight
or
an
incorrect
weight
(repeatedly)
Packaging
/
transport
safeguard
has
not
been
fully
removed
Check
the
scales
Scales
are
maladjusted
Recalibrate
the
scales
Sensor
is
damaged
Replace
the
sensor
and
recalibrate
the
scales
Load
lever
system
is
damaged
or
transfer
of
force
to
the
sensor
is
interrupted
Check
the
base
frame
(if
present,
the
tie
rod)
for
damage
or
incorrect
assembly
Incomplete
digits
Display
is
defective
Replace
the
electronics
Malfunction
during
the
weighing
procedure
Display:
E
r
:x:n
o
The
electronics
have
detected
an
error.
X:
module
number
No:
error
number
Er
:x:
10
Sensor
is
defective
or
not
properly
connected
Check
and,
if
necessary,
replace
the
sensor
(if
the
sensor
is
replaced,
a
recalibration
is
required)
Er
:x:
11
Sensor
is
defective
or
supply
lines
are
damaged
Check
the
input
lines;
check
and,
if
necessary,
replace
the
sensor
(if
the
sensor
is
replaced,
a
recalibration
is
required)
Er
:x:
12
Initial
load
is
too
high
Check
the
load
lever
(stuck
or
bent;
check
the
sensor,
replace
it
if
necessary
and
carry
out
a
recalibration
07.07.99-
Meyer
30-34-00-588