Reset to Factory Default , Page 3 of 10
2015
1. Introduction
To reset a Secomea appliance like a TrustGate or a SiteManager you will
need to connect a computer to the appliance using the serial interface. If you
have the password to the appliance you can reset the appliance from the
WEB GUI Maintenance menu and don't need to follow these instructions.
Resetting an appliance will clear all configurations and you will need to re-
configure the unit from scratch.
The default user name is admin and default password is admin.
Hint! If in case you have use the Appliance Launcher for configuring the Ap-
pliance the password might have been set to MAC address like:
00:00:24:CA:CB:D1 ( all capital letters and separated by colon “:”)
2. Cable and Application
You will need a standard null-modem cable (DB9 Female to Female) cable,
pin layout is a shown:
If you are using a Windows computer you can with advantage use the Hy-
perTerminal application or a similar telnet application.
2.1. TrustGate 164, 264 and 560R
Included in the package you will find a console cable (DB9-RJ45).