TRACKSO INSTALLATION GUIDE FOR SECURE METER
Brand: Secure
Type: Multi-line Digital Display Panel Meter
Models: Elite 440
CONNECTION DIAGRAM
On the rear panel, Secure Elite 440 has an RS-485 communication socket as shown in the following figure.
Figure S1 Rear view of Secure Elite 440
1. Please unscrew the RS485 terminal as shown in Figure S1.
2. Connect the cables to the RS485 bus terminal blocks.
3. Please make the connections from Terminal Block chip to TrackSo IoT
Gateway as mentioned in the Table ST1.
Table ST1 Secure RS485 chip connections
with TrackSo IoT Gateway
Secure Pin No. &
Assignment
TrackSo Pin No. &
Assignment
1
A
3
D+
2
B
4
D-
3
SG
-
-
DEFAULT CONFIGURATION IN TRACKSO IOT GATEWAY
Inverter ID: 1 (Range: 1 to 247)
Baud Rate: 9600 (Default) (Values: 9600, 19200, 38400)
Data Bits: 8
Stop Bit: 1
Parity: N/A (None)
CONFIGURATION AT THE METER END
The Setup Mode can be used to configure the meter with the help of push buttons: The Setup Mode is password protected which
can be accessed only by users authorized to change the configurations
Password Entry
The following steps will guide you to access the Setup Menu:
Question and Answer IconNeed help?

Do you have a question about the Secure Elite 440 and is the answer not in the manual?

Secure Elite 440 Specifications

General IconGeneral
BrandSecure
ModelElite 440
CategoryMeasuring Instruments
LanguageEnglish

Summary

Secure Elite 440 Connection and Basic Configuration

Connection Diagram and RS485 Wiring

Illustrates the RS485 communication socket and wiring connections for the Secure Elite 440.

Default TrackSo IoT Gateway Settings

Specifies default Inverter ID, Baud Rate, Data Bits, Stop Bit, and Parity for the TrackSo IoT Gateway.

Accessing Meter Setup Menu and Password Entry

Guides on accessing the meter's setup mode using push buttons and the default password.

Setting Meter Communication Parameters

Details configuring the meter's Baud Rate and Modbus ID through the setup menu.

TrackSo IoT Gateway Operation and Monitoring

Connecting Multiple Meters

Shows how to wire multiple Secure Elite meters to the TrackSo IoT Gateway for serial communication.

TrackSo Device Installation and LED Status

Covers TrackSo device working, SIM insertion, power-on steps, and LED status indicators.

Network and Data Status Checks

Explains checking network status via SMS and monitoring unit data reception on the TrackSo platform.

Troubleshooting Data Ingestion Issues

Guides on checking event ingestion logs for troubleshooting data flow and connection issues.