TRACKSO INSTALLATION GUIDE FOR SECURE METER
Brand: Secure
Type: Multi-line Digital Display Panel Meter
Models: Elite 440
CONNECTION DIAGRAM
On the rear panel, Secure Elite 440 has an RS-485 communication socket as shown in the following figure.
Figure S1 Rear view of Secure Elite 440
1. Please unscrew the RS485 terminal as shown in Figure S1.
2. Connect the cables to the RS485 bus terminal blocks.
3. Please make the connections from Terminal Block chip to TrackSo IoT
Gateway as mentioned in the Table ST1.
Table ST1 Secure RS485 chip connections
with TrackSo IoT Gateway
Secure Pin No. &
Assignment
TrackSo Pin No. &
Assignment
1
A
3
D+
2
B
4
D-
3
SG
-
-
DEFAULT CONFIGURATION IN TRACKSO IOT GATEWAY
Inverter ID: 1 (Range: 1 to 247)
Baud Rate: 9600 (Default) (Values: 9600, 19200, 38400)
Data Bits: 8
Stop Bit: 1
Parity: N/A (None)
CONFIGURATION AT THE METER END
The Setup Mode can be used to configure the meter with the help of push buttons: The Setup Mode is password protected which
can be accessed only by users authorized to change the configurations
Password Entry
The following steps will guide you to access the Setup Menu:
Question and Answer IconNeed help?

Do you have a question about the Secure Elite 440 and is the answer not in the manual?

Summary

Secure Elite 440 Connection and Basic Configuration

Connection Diagram and RS485 Wiring

Illustrates the RS485 communication socket and wiring connections for the Secure Elite 440.

Default TrackSo IoT Gateway Settings

Specifies default Inverter ID, Baud Rate, Data Bits, Stop Bit, and Parity for the TrackSo IoT Gateway.

Accessing Meter Setup Menu and Password Entry

Guides on accessing the meter's setup mode using push buttons and the default password.

Setting Meter Communication Parameters

Details configuring the meter's Baud Rate and Modbus ID through the setup menu.

TrackSo IoT Gateway Operation and Monitoring

Connecting Multiple Meters

Shows how to wire multiple Secure Elite meters to the TrackSo IoT Gateway for serial communication.

TrackSo Device Installation and LED Status

Covers TrackSo device working, SIM insertion, power-on steps, and LED status indicators.

Network and Data Status Checks

Explains checking network status via SMS and monitoring unit data reception on the TrackSo platform.

Troubleshooting Data Ingestion Issues

Guides on checking event ingestion logs for troubleshooting data flow and connection issues.

Installation Video Guide

Summary

Secure Elite 440 Connection and Basic Configuration

Connection Diagram and RS485 Wiring

Illustrates the RS485 communication socket and wiring connections for the Secure Elite 440.

Default TrackSo IoT Gateway Settings

Specifies default Inverter ID, Baud Rate, Data Bits, Stop Bit, and Parity for the TrackSo IoT Gateway.

Accessing Meter Setup Menu and Password Entry

Guides on accessing the meter's setup mode using push buttons and the default password.

Setting Meter Communication Parameters

Details configuring the meter's Baud Rate and Modbus ID through the setup menu.

TrackSo IoT Gateway Operation and Monitoring

Connecting Multiple Meters

Shows how to wire multiple Secure Elite meters to the TrackSo IoT Gateway for serial communication.

TrackSo Device Installation and LED Status

Covers TrackSo device working, SIM insertion, power-on steps, and LED status indicators.

Network and Data Status Checks

Explains checking network status via SMS and monitoring unit data reception on the TrackSo platform.

Troubleshooting Data Ingestion Issues

Guides on checking event ingestion logs for troubleshooting data flow and connection issues.

Installation Video Guide

Overview

The Secure Elite 440 is a multi-line digital display panel meter designed for energy management, integrating with the TrackSo IoT Gateway for remote monitoring and data transmission. This device is suitable for various applications requiring accurate measurement and remote access to energy data.

Function Description

The Secure Elite 440 meter measures and displays various electrical parameters. Its primary function is to provide real-time energy data, which can then be transmitted to an IoT platform for comprehensive energy management. The meter supports RS-485 communication, allowing it to connect to an IoT gateway like the TrackSo device. This integration enables remote monitoring, data logging, and analysis of energy consumption. The device also features a setup mode for configuring parameters such as baud rate and MODBUS ID, ensuring flexibility in different network environments.

Important Technical Specifications

  • Brand: Secure
  • Type: Multi-line Digital Display Panel Meter
  • Models: Elite 440
  • Communication Interface: RS-485 socket on the rear panel.
  • Configurable Baud Rates: 1200, 2400, 4800, 9600 (default), 19200, 38400 bps.
  • Data Bits: 8 (default)
  • Stop Bit: 1 (default)
  • Parity: N/A (None) (default)
  • Configurable MODBUS ID Range: 1 to 247.
  • Power Requirement for TrackSo IoT Gateway: Minimum 12V/1A input.

Usage Features

Connection and Setup: The Elite 440 connects to the TrackSo IoT Gateway via its RS-485 terminal. The connection involves unscrewing the RS485 terminal, connecting cables to the bus terminal blocks, and then linking these to the TrackSo IoT Gateway according to the specified pin assignments (Secure Pin 1 (A) to TrackSo Pin 3 (D+), Secure Pin 2 (B) to TrackSo Pin 4 (D-), and Secure Pin 3 (SG) to TrackSo SG).

Configuration at the Meter End: The meter's setup mode is accessible via push buttons and is password-protected (default password: '1234').

  1. Accessing Setup Mode: From the default display, press the designated button to enter the Setup Mode page.
  2. Password Entry: Navigate to the 'Set Up' option, confirm, and then enter the 4-digit password using the up/down buttons, confirming with the designated button. Correct entry grants access to the configuration mode; incorrect entry displays an 'Incorrect' message and returns to the Setup Mode page.
  3. Setting Baud Rate: Within the setup menu, select the 'Communication' option. Then, choose 'BD RATE' to access the baud rate configuration page. Users can select from configurable baud rates (1200, 2400, 4800, 9600, 19200, 38400 bps) using left/right buttons and confirm the selection.
  4. Setting MODBUS ID: From the 'Communication' page, select 'MODBUS ID'. Enter the desired ID within the permissible range of 1 to 247 and confirm.
  5. Saving Configurations: After making changes, select the 'Save' option to activate the new configurations. The meter will then save the settings and return to the previous page, or automatically after 5 seconds.

TrackSo IoT Gateway Operation:

  1. SIM Card Insertion: Ensure correct connections and insert the SIM card into the TrackSo IoT Gateway by pulling the SIM tray, placing the card inside, and pushing the tray back into the slot.
  2. Power On: Switch on the power to the TrackSo device (minimum 12V/1A input). The red Power LED will glow and stay ON.
  3. GPRS Network Availability: The TrackSo IoT Gateway will only send data if a GPRS network is available at the installation location.

LED Indicators on TrackSo IoT Gateway:

  • GREEN (Power): Light when the device is powered on.
  • RED (GSM):
    • Flashing (ON 100ms, OFF 100ms): SIM Card not found.
    • Flashing (ON 500ms, OFF 500ms): Searching for GSM Network.
    • Flashing (ON 0.1s, OFF 2.9s) Once every 3sec: GSM Network Registered.
    • Flashing twice every 3sec: GPRS IP Connected.
    • Flashing 5 times: GPRS IP Sending data.
    • LED OFF: GSM Fault.
  • GREEN (COM TX): Blinks on data transmission in RS485 port.
  • YELLOW (COM RX): Blinks on data reception in RS485 port.

Connecting Multiple Meters: The TrackSo IoT Gateway supports connecting multiple Secure Elite 440 meters in a daisy-chain configuration via their RS-485 ports. Each meter's D+, D-, and SG terminals are connected in parallel to the corresponding terminals on the gateway.

Checking Network Status and Data Reception:

  1. SMS Command: Send the SMS command *2222#<Stat.gsm> to the mobile number of the TrackSo device to receive a status message detailing IMEI, network, signal strength, GPRS connection status, PIP connection status, and logged data points.
  2. Online Monitoring: If the GSM light flashes 5 times (indicating GPRS IP Sending data), log in to www.trackso.in with your username/password.
  3. View Units: Click on 'Units' from the menu bar to view installed units. Check if the 'Status' for the relevant unit is 'Receiving'.
  4. Event Ingestion Logs: If the status remains 'Not receiving' for more than 10 minutes, check 'Event Ingestion Logs' under your email ID on the TrackSo platform. If logs show 'Invalid request', restart the device. If logs are still problematic, contact support.

Maintenance Features

  • Password Protection: The setup mode is password-protected, ensuring that only authorized users can change critical configurations, preventing accidental or unauthorized alterations.
  • LED Indicators: Comprehensive LED indicators on the TrackSo IoT Gateway provide immediate visual feedback on power status, SIM card detection, GSM network activity, GPRS connectivity, and RS485 communication, aiding in quick troubleshooting.
  • Remote Monitoring and Diagnostics: The integration with the TrackSo IoT platform allows for remote monitoring of device status and data reception. The 'Event Ingestion Logs' feature helps diagnose issues related to data transmission from the gateway.
  • Installation Video: An installation video is provided (via shortlink and YouTube link) to guide users through the setup process, ensuring correct installation and configuration.
  • Support Contact: Contact information (we@freespirits.in) is provided for any enquiries or issues that cannot be resolved through the provided documentation and troubleshooting steps.

Secure Elite 440 Specifications

General IconGeneral
BrandSecure
ModelElite 440
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals