Questions and Answers

  • R
    Ronald GlassAug 8, 2025
    Why is my Seeley Accessories cooler not cooling enough?
    • V
      velezlauraAug 8, 2025
      If your Seeley Accessories cooler isn't cooling adequately, it might be due to several reasons. The cooler or ducts might be too small, in which case you should replace them with larger ones. The cooling cores or inlet air filter could be clogged or dirty, requiring replacement or cleaning. Another cause could be dry cores or a lack of water; inspect the water distribution system and pump for obstructions. Also, ensure there are enough air discharge openings and exhaust to prevent high humidity. Check for obstructions in the exhaust air duct. Note that on days with excessive ambient humidity, the cooler's performance will be reduced, and there is no fix for this.
  • L
    Lindsay ThompsonAug 12, 2025
    How to fix a noisy Seeley Accessories cooler?
    • J
      Joseph DunnAug 12, 2025
      If your Seeley Accessories cooler is making excessive noise, the fan might be unbalanced due to dirt, so try cleaning it. Alternatively, the air distribution system could be creating too much back pressure due to design issues, so have a contractor re-evaluate it and consider using bends instead of elbows, or changing grille sizes. Another possibility is that the attenuator is directing noise in the wrong direction, so attach it to direct sound in a different direction.
  • M
    Melanie EvansAug 16, 2025
    What to do if water is being blown into the building from my Seeley Climate Wizard CW-P15?
    • V
      Victoria SmithAug 16, 2025
      If water is being blown into the building from your Seeley Accessories, the auto drain valve might be malfunctioning, so check and fix its function. The supply drain plenum could also be blocked, so unblock it. Also, loose water hose connections can cause this issue, so tighten them. Finally, check for cracked or broken hoses and replace them if necessary.
  • T
    Tyler MillerAug 21, 2025
    What to do if the fan on my Seeley Climate Wizard CW-P15 fails to start?
    • T
      Travis RubioAug 21, 2025
      If your Seeley Accessories fan fails to start, first check the main power circuit breaker or fuse and reset or replace it. If the motor is burned out, replace it. Low system voltage can also be a cause, so consult with your power supply authority. Check for any fault conditions indicated by the wall control unit or the tri-color LED on the cooler electronics module and rectify the fault. If the wall control has failed, replace it. Finally, if the control is in AUTO or AUTO TIMER mode without fan bars displayed, switch to MANUAL mode to check the fan operation.
  • C
    Cheryl JohnsonAug 26, 2025
    How to get rid of unpleasant odor from Seeley Climate Wizard CW-P15?
    • S
      Scott EdwardsAug 26, 2025
      If your Seeley Accessories has an unpleasant odor, it could be due to the cooler's location near a source of the odor, in which case you should remove the source or relocate the cooler. Algae in the tank water can also cause this, so drain the pan, clean it thoroughly, refill it, and change the pads. Clean or replace the chlorinators. If the pads remain wet after shutdown, run the fan on "vent" for 3 hours to dry them out. Heavy core deposits can also cause odors, so replace the cores.
  • L
    Leslie WaltonAug 30, 2025
    Why is my Seeley Accessories pump running but there is no water circulation?
    • C
      Carolyn LindseyAug 30, 2025
      If the pump in your Seeley Accessories runs but there is no water circulation, or the pads lack water, check if there is sufficient water in the reservoir. Ensure the probe cable is fully plugged in and clean the probes. Also, check for blocked water hoses and clean out any blockages. Lastly, check for a blocked pump cavitation plate and clean it.
  • S
    Stephanie WilliamsSep 2, 2025
    Why is my Seeley Climate Wizard CW-P15 continuously overflowing water?
    • J
      Justin EdwardsSep 2, 2025
      If your Seeley Accessories is continuously overflowing water, the water management probes adjustment is likely incorrect. Check that the probe cable is fully plugged in and clean the probes.