INSTALLATION & OPERATION MANUAL
CTA250 and CTA500 Evaporative Cooler
Original English Instructions

Questions and Answers

  • R
    ryan39Aug 17, 2025
    Why is my Seeley Air Cleaner not cooling properly?
    • C
      crayAug 17, 2025
      Your Seeley Air Cleaner might not be cooling effectively due to several reasons. The cooler might be under-sized, in which case you should replace it with a larger one. The ducts could be too small; consider a cooling load design to determine the correct size for the unit, ducting, and outlets. Clogged or dirty cooling pads can also cause this issue, so clean or replace them. If the pads are dry or there's a lack of water, check the water distribution system for obstructions in the hoses and inspect the pump. Ensure adequate exhaust from the building by opening windows and doors to prevent high humidity. Finally, excessive ambient humidity can limit cooling performance; on such days, shutting off the pump may be necessary.
  • P
    Paul PopeAug 20, 2025
    What to do if the pump fails to operate on my Seeley Air Cleaner?
    • O
      omartinezAug 20, 2025
      If the pump on your Seeley Air Cleaner fails to operate, first check the fuse and replace it if blown, after checking the pump for faults. If the fuse isn't the issue, the pump motor may have failed, requiring a replacement of the pump.
  • B
    Bernard CampbellAug 22, 2025
    What to do if the fan fails to start on my Seeley Air Cleaner?
    • G
      Gerald HutchinsonAug 22, 2025
      If the fan on your Seeley Air Cleaner isn't starting, check the motor fuse and replace it if it's blown, after identifying the cause of the overload. If the fuse is not the problem, the fan motor might be burned out and need replacement. Also, low system voltage could be the cause, in this case you should consult with your power supply authority.
  • S
    Sarah BrownAug 25, 2025
    How to fix a noisy Seeley Air Cleaner?
    • K
      kellylarryAug 26, 2025
      A noisy Seeley Air Cleaner could be due to a fan being out of balance because of dirt; cleaning the fan might resolve this. Alternatively, there might be too much back pressure, requiring a re-evaluation of the design, improvement of the duct layout, or changes to grille sizes.
  • L
    Linda ElliottAug 27, 2025
    Why is my Seeley Air Cleaner pump running but there is no water circulation?
    • W
      Whitney GonzalezAug 27, 2025
      If your Seeley Air Cleaner pump is running but there's no water circulation, it could be due to several reasons. The water level in the tank might be insufficient, so adjust the float level. There might be a blockage in the water line that you need to check and clean out. The pump strainer could also be blocked, requiring cleaning. Finally, insufficient water supply pressure could be the issue, so check and confirm the water supply pressure.
  • K
    Kristi SanchezAug 30, 2025
    What causes continuous overflow of water in Seeley Air Cleaner and how to fix it?
    • R
      Rachel JohnstonAug 30, 2025
      Continuous overflow of water in your Seeley Air Cleaner can be caused by an incorrect float valve adjustment; adjust the float valve to correct this. Heavy pad deposits can also cause this issue, so clean or replace the pads.
  • I
    Ian MillerSep 1, 2025
    How to get rid of the unpleasant odour from my Seeley Air Cleaner?
    • O
      operezSep 2, 2025
      An unpleasant odour from your Seeley Air Cleaner can stem from several causes. New cooler pads may emit an odour initially; fill the tank, run the pump briefly to wash the pads, drain the tank, refill, and repeat if needed. This smell should dissipate after some hours of operation. The cooler might be near a source of unpleasant odour, so remove the source or relocate the cooler. Algae in the tank water can also cause this; drain the pan, clean it thoroughly with a strong cleansing agent, refill it, and change the pads. If pads remain wet after shutdown, run the fan on 'vent/fan' for 10 minutes after cooling to dry them. Heavy pad deposits may also be the cause, so clean or replace the pads.
  • D
    Douglas Smith MDSep 4, 2025
    What to do if water is entering the cooler outlet of my Seeley Air Cleaner?
    • J
      Jared YangSep 4, 2025
      If water is entering the cooler outlet of your Seeley Air Cleaner, check for loose water hose connections and tighten them. Look for broken water hoses and replace any cracked or broken ones. Ensure the cover is fitted on the float valve; if not, replace the float valve. Verify that the pads are correctly fitted into the pad frames and install them correctly if needed. Finally, incorrect or damaged pads can cause this issue, so replace them with new Chillcel pads.
  • R
    Rachel HarrisonSep 6, 2025
    What to do if Seeley Convair CTA500 Accessories cooling pads are dirty?
    • E
      Edward JohnsonSep 7, 2025
      If your Seeley Accessories cooler isn't cooling effectively due to clogged or dirty cooling pads, try cleaning or replacing the pads to improve performance.
  • J
    Jacob GardnerSep 9, 2025
    What to do if Seeley Accessories cooler pads are dry?
    • M
      michelle69Sep 9, 2025
      If the Seeley Accessories cooler pads are dry or lack water while operating, examine the water distribution system for obstructions in the hoses and check the pump to ensure proper water flow.

Summary

Important Safety Instructions

Read and Save Instructions

Instructions must be read and saved for future reference to ensure safe operation.

General Warnings

Key warnings to reduce risks of fire, electric shock, or injury during operation.

Installer Risk Assessment

Guidance for installers on conducting risk assessments for hazardous tasks.

Quick Guide

Safety First

Emphasizes reading and understanding safety sections before proceeding with installation.

Commissioning the Cooler

Steps for commissioning the cooler, including switching on power and testing.

INSTALLATION

Cooler Location

Guidance on selecting the optimal location for the cooler, considering structural and environmental factors.

Mounting the Roof Jack

Steps for installing and securely fixing the roof jack to the roof structure.

Water Requirements

Specifications for cooler water supply, including pressure, flow, and temperature.

Mains Water Connection

Connecting the main water supply to the cooler, including shut-off valve requirements.

Electrical Requirements

Specifies electrical supply requirements, circuit protection, and wiring diagrams.

Setting the Water Level

Adjusting the float valve to achieve the correct water level in the cooler's pan.

COMMISSIONING THE COOLER

Commissioning Completion Checklist

A checklist to ensure all installation and commissioning steps are completed correctly.

Customer Handover

Explaining cooler operation, maintenance, and providing documentation to the customer.

TROUBLE SHOOTING

Inadequate Cooling

Diagnosing and resolving issues related to insufficient cooling performance.

Pump Runs but No Water Circulation or Pads Lack Water

Resolving issues where the pump runs but water is not reaching the pads.

Unpleasant Odour

Identifying and resolving causes of unpleasant odors from the cooler.

USER SAFETY

Important Safety Instructions

Crucial safety instructions for operating the evaporative cooler safely.

Warranty and Maintenance Requirements

Details on how maintenance compliance is a condition of warranty coverage.

MAINTENANCE

Maintenance Schedule Servicing

Importance of regular servicing by qualified technicians for efficient cooler operation.

Access for Servicing and Maintenance

Safety precautions and required clearances for accessing the cooler for maintenance.

Residential Maintenance Schedule

Schedule of component checks and actions required every 2 years for residential coolers.

Commercial; Industrial Maintenance Schedule

Maintenance schedule for commercial/industrial coolers, performed quarterly or twice yearly.