32
|
SLAVE CONTROLLERS
Multiple MagIQtouch Controllers can be used to control individual
zones. In such installations there is always one “master controller”
located in a nominated “master zone”. All other controllers become
“slave controllers”.
In such systems certain principles that apply:
If the master controller is set to OFF, no other zone can be
turned on.
If the master controller is set to ON, zones can be turned on and
o󰀨 from the slave controllers.
The primary operating mode (HEAT, COOL and FAN ONLY) is
dictated by the master controller and cannot be changed by a
slave controller.
The SETTINGS menu in a slave controller will only display
options relevant for the applicable zone.
For Evaporative Cooling:
The Master Controller is the only active controller.
The set temperature or fan speed can only be modied by the
Master Controller.
For Gas Ducted Heating / Integrated Cooling:
The secondary operating mode (MANUAL and PROGRAM) can
be selected for each zone from the master and slave controllers.
The set temperature is unique for each zone and is set from the
controller located within the zone (either master or slave).
No fan speed limit control is available. Fan speed is
automatically controlled by the heater to achieve the set
temperature.