Date Code 20160329 SEL-651RA Recloser Control
Introduction
This 3-pin cable for input power provides a three-pin male receptacle that
exits from the bottom of the cabinet. The 3-pin cable for input power is
internally wired to the control module’s power supply terminals. Therefore,
the 3-pin cable for input power also supplies power to the outlet and/or any
other accessories effectively connected in parallel with the power supply
terminal. The 3-pin receptacle provides a means (by way of an external cable,
which is not included) to connect input power to the control.
Parts
Installation
Step 1. Install the 3-pin cable for input power in the bottom of the
cabinet in the leftmost hole in the front row. Insert the
receptacle from the inside of the cabinet and the four screws
from the outside. Install the nuts on the screws from the inside
of the cabinet. See Figure 1.
Figure 1 Install Ring Terminal
SEL Part Number Description Quantity
SEL-C2261 3-pin cable for input power 1
080-0101 5/8 steel wire clamp 2
140-0500 4-40 x 1/2" screw 4
140-0740 4-40 hex nut 4
144-0140 Plastic cap 1
310-0050 Zip ties 12
SEL-651RA Installation Instructions for
3-Pin Cable for Input Power
Question and Answer IconNeed help?

Do you have a question about the Sel 651R and is the answer not in the manual?

Sel 651R Specifications

General IconGeneral
Storage Temperature-40°C to +85°C
Model651R
ProtectionOvervoltage
ControlLogic
CommunicationEthernet
DisplayLCD
Relative Humidity95% non-condensing
Communication PortsEthernet

Summary

Introduction

Parts List

Installation Procedure

Install 3-Pin Cable Receptacle

Install the 3-pin cable receptacle in the bottom of the cabinet from the inside.

Wiring Without Fuse Block

Form Drip Loop and Route Harness Wires

Form a drip loop and route harness wires to the 14-pin connector.

Secure Wires on Control Module

Secure wires to the top of the control module with accessory wire clamps.

Attach 3-Pin Cable to Control Module Terminals

Attach white wire to B26 and black wire to B21 terminal on the control module.

Wiring With Fuse Block

Route Harness Wires to Fuse Block

Form a drip loop and route harness wires to the bottom of the fuse block.

Attach 3-Pin Cable to Fuse Block Terminals

Attach white wire to N1 fuse and black wire to L1 fuse on the fuse block.

Wiring Diagrams

Diagram: Without Fuse Block

Wiring diagram illustrating connections without a fuse block.

Diagram: With Fuse Block

Wiring diagram illustrating connections with a fuse block.

Factory Assistance