1
© 2020
Sencon’s 11-487-00 Short Can Sensor can be used to replace the following sensors: 9-287-03, 11-287-63, 11-287-33,
11-287-53, 9H-387-56, 11-387-S1.
The 11-487-00 is a direct replacement for some of the sensors above while others will require a wiring change in the
bodymaker.
Current Sensor  
9-287-03 or 11-287-63 Direct swap -See wiring diagram Fig:1 or Fig:2 22-487-03/63 (default)
11-287-33 or 11-287-53 Direct swap -See wiring diagram Fig: 1 or Fig:2 
387 Sensor interfaced to a
BCM387 module
Remove BCM387 module,
Wire 487 directly to bodymakers PLC Fig: 1 or Fig:2
Depends on the type of punch
being used see punch chart below.
387 Sensor interfaced to a
BCM500 module
Wire 487 sensor to BCM500
module as per diagram Fig:3
Depends on the type of punch
being used see punch chart below.
The SENCON 11-487-00 is a self-contained metal
discriminator proximity switch; an excellent choice for
can line machine control. The sensor detects wall-ironed
aluminum over carbide tooling and is designed to act as
“short can” detector to protect the tooling in wall ironing
machines.
The integral electronics interface directly with
discrete logic or computer controlled systems and
are encapsulated inside an all metal housing. This

humidity. Thermal stability and repeatability provide reliable
performance over a wide temperature range.





current punch types.


487 Short Can Sensor guide
Short Can Timing Window
The short can window dictates when the sensors output is


sensor is 100% covered by the punch at around 135
0

the top of the can just starts to uncover the sensor at 155
0
this depends on the height of the can body, and is typically
between 155
0
and 165
0
.


displayed from the control system.
Contents
 ....1
 .......1
Punch Assessment ..............2
...........3
.............5
Introduction to the 487 sensor
PC Client Interface ..............6
 ...........7
 ................9
 .....................9
 .......10