USING THE RELAY MANAGEMENT FUNCTIONS (STEPS 71 through 79)
Purpose To allow you to either activate or deactivate a specified relay while in the
programming mode.
Format 7 + relay command code (1 digit) + #.
Relay
Command 1 = Cycle relay 1 for its programmed period of time.
Codes 2 = Cycle relay 2 for its programmed period of time.
3 = Latch relay 1 for an unspecified amount of time.
4 = Latch relay 2 for an unspecified amount of time.
5 = Release relay 1 from its latched state.
6 = Release relay 2 from its latched state.
7 = Cycle both relays for their programmed period of time.
8 = Latch both relays for an unspecified amount of time.
9 = Release both relays from their latched state.
Example 7 + 2 + # (cycles relay 2 for its programmed period of time).
Important If you select relay action code “9” and only one of the relays are currently
Notes latched, this step will not affect the status of the unlatched relay.