24
Maintenance and care: Preventative maintenance
Maintenance and care
Preventative maintenance
The dehumidier requires very little attention for trouble free running. All the necessary
safety and control functions have been built in. The fan motor(s) and the compressor have
permanent lubrication and require no particular maintenance.
Injury - risk of cuts and minor skin burns, when you access the inside of the SET
Be cautious of sharp edges when opening the unit. Internal parts can be very hot or cold.
• Switch o SET for half an hour prior to opening it. Avoid touching very hot and cold parts
as e.g. the pipes or evaporator.
• Avoid touching sharp edges or wear gloves.
The air inlet lter is to be cleaned once a month. The lter is placed in a stand behind the grill
of the air inlet duct. Drip tray and outlet should also be cleaned, so water can run o freely.
Please follow this procedure to perform the monthly service:
Step Action
1 Unlock the two locks underneath the dehumidier
2 Dismount the front cap by lifting it up and take out the lter.
The lter is located on the rear of the front cap
3 Wash the lter in tepid soapy water or vacuum clean thoroughly.
If the lter is faulty, replace it.
4 Insert lter in the lter holder, reattach the cap and lock the two locks. (From Step 1)
NB: If the lter (one size PPI lter with order no. 094686) has to be replaced, you can order it
through a SET dealer.
The dehumidier should be inspected once a year.
Please follow this procedure to perform the annual service:
Step Action
1 Remove the front from the dehumidier
2 Inspect the inside of the dehumidier
3 Vacuum clean the dehumidier to remove any dust or debris
Important: Vacuum clean the condenser thoroughly
4 If necessary wash the lamella evaporator in tepid soapy water if it is badly soiled
Introduction
CAUTION
Monthly service