Cooling
These device uses passive convection cooling. For this
reason sufficient air circulation should be guaranteed.
The amount of cooling needed depends on the ambient
temperature, the transmission power and the intensity of data
traffic.
If operating at extremes ensure that proper clearances, as
shown in drawing, are given.
Avoid exposure to direct sunlight.
Mounting
This device is equipped with a spring-loaded clip to hold the
device on a standard 35 mm DIN rail.
The device is intended to be mounted vertically.
The top of the hook must first be set on the DIN rail. Then just
press down (step 1) and at the same time rotate the device
until it is flush with the rail (step 2). Finally, release the force on
the spring and check that it gets properly seated.