EasyManua.ls Logo

sewerin EX-TEC PM 4 - Page 86

sewerin EX-TEC PM 4
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
77
Appendix
Kerosene JFUEL (100 % LEL = 0.70 % vol.)
Area of
application
Test gas Tolerances / fresh
air zero point
Tolerances / test
gas indication
accuracy
ppm range Replacement test
gas
0.30 % vol. C
3
H
8
in synth. air (dis-
play setpoint
when adding re-
placement gas:
0.32 % vol.)
0 ppm 0.3 to 0.4 % vol.
% LEL range
-0.04 to +0.04 % vol.
(-4 to +4 % LEL)
0.28 to 0.36 % vol.
(44 to 52 % LEL)
% vol. range
Adjustment not
possible
– –
Hydrogen H
2
(100 % LEL = 4.00 % vol.)
Area of
application
Test gas Tolerances / fresh
air zero point
Tolerances / test
gas indication
accuracy
ppm range
1.0 % vol. H
2
in
synth. air
0 ppm
0.8 to 1.2 % vol.
% LEL range
2.0 % vol.
(50 % LEL) H
2
in
synth. air
-0.12 to +0.12 % vol.
(-3 to +3 % LEL)
1.80 to 2.20 % vol
(45 to 55 % LEL)
% vol. range
Adjustment not
possible
– –
Acetylene C
2
H
2
(100 % LEL = 2.30 % vol.)
Area of
application
Test gas Tolerances / fresh
air zero point
Tolerances / test
gas indication
accuracy
ppm range
Adjustment not
possible
– –
% LEL range
1.00 % vol.
(43 % LEL) C
2
H
2
in
synth. air
-0.07 to +0.07 % vol.
(-3 to +3 % LEL)
0.88 to 1.12 % vol.
(38 to 48 % LEL)
% vol. range
Adjustment not
possible
– –