ADVICE
PIPE SUPPORTS
All฀sanitary฀pipe฀work฀must฀be
supported,฀in฀accordance฀with฀the฀pipe
manufacturer’s฀recommendations.
Avoid฀dipping฀or฀trapping,฀which฀may
cause฀the฀build฀up฀of฀residual฀“solids”
and฀sub-฀sequent฀blockage.
BENDS
Where฀possible฀long฀sweeping฀bends
should฀be฀used.฀Do฀not฀use฀short
elbows.฀If฀sweeping฀90°฀elbows฀are
not฀available฀use฀two฀45°฀elbows฀to
make฀a฀90°฀turn.
PIPE WORK
All฀pipe฀work฀should฀be฀either฀copper,
PVC฀or฀CPVC฀(Do฀not฀use฀flexible
pipes).฀Hangers฀should฀not฀be฀less฀than
three฀feet฀apart฀to฀prevent฀pipe฀rattling.
DISCHARGE
Never฀discharge฀directly฀into฀an฀open
drain,฀fixture,฀manhole฀or฀rainwater
drainpipe.฀It฀is฀illegal฀for฀it฀constitutes
a฀health฀hazard.฀Direct฀connections฀into
sanitary฀waste฀systems฀only,฀shall฀be
acceptable.
FREEZING
Ensure฀all฀pipe฀work฀susceptible฀to
freezing฀is฀adequately฀insulated฀or
heated.฀In฀unheated฀buildings,฀the
toilet,฀piping฀and฀macerating฀unit฀must
be฀properly฀winterized฀with฀“RV฀or
plumbers”฀anti-freeze฀or฀drained
completely.
ELECTRICITY
Before฀attempting฀any฀maintenance฀or฀servicing,฀the฀unit฀must
be฀disconnected฀from฀the฀power฀source.฀The฀macerating
system฀must฀be฀connected฀to฀a฀Ground฀Fault฀Circuit฀Interrupter
(GFCI).
VERTICAL INSTALLATION FIRST
Any฀initial฀horizontal฀pipe฀run฀from฀the
unit,฀prior฀to฀a฀vertical฀lift฀should฀not
exceed฀12-18฀inches.
EASY ACCESS
The฀unit฀should฀be฀accessible฀and฀remo-
vable฀in฀the฀event฀of฀maintenance฀being
required.฀During฀the฀installation฀a฀full-port
ball฀valve฀should฀be฀installed฀at฀the฀base฀of
any฀vertical฀discharge฀pipe฀work฀from฀the
unit฀to฀allow฀easy฀service฀of฀the฀unit.
GRAVITY FALL
The฀unit฀accepts฀wastewater฀by฀gravity;
it฀does฀not฀“vacuum”฀in฀water.฀All฀inlet
pipe฀work฀must฀have฀a฀positive฀gravity
fall,฀(1/4”฀per฀foot).฀All฀horizontal฀piping
from฀the฀macerating฀unit฀must฀also฀have
a฀positive฀gravity฀fall฀to฀allow฀free
drainage฀when฀the฀pump฀stops.
NO DIAGONAL “UPHILL”
PIPE RUNS
All฀discharge฀pipe฀work฀from฀the฀unit
should฀run฀either฀directly฀vertical฀upwards
from฀it฀or฀in฀a฀horizontal฀plane฀(with฀a฀small
gravity฀flow)฀to฀the฀point฀of฀discharge.
Pipe฀work฀should฀not฀be฀installed฀with
diagonal฀upward฀slope฀from฀the฀unit฀to
the฀point฀of฀discharge.