4T-C6070AH1X
5 – 8
  2.          WHITE BALANCE ADJUSTMENT/ GAMMA ADJUSTMENT 
a) 
1) White Balance Adjustment / Gamma Adjustment 
 
 
NO.
 
 
ITEM 
 
CONDITION 
 
PROCEDURE 
 
 
i 
 
Setting 
 
AV Mode : DYNAMIC 
Backlight : MAX   
ECO : OFF 
Set the luminance 
meter on the centre 
of the screen 
 
For the details of white balance adjustment procedure, please refer to white balance   
adjustment spec for Kameyama model. 
1. Confirm the set condition. 
2. Connect the white balance jig [3.5mm H/P Jack (4 point)] 
3. Through RS-232C command, adjustment mode screen is displayed.
 
 
ii 
 
Auto 
Adjustment 
 
 
 
 
 
[command] 
Adjustment 
Mode 
KRSW0001 
KKT10037 
 
Setting 
KYOF0001 
OSDS0001 
SBSL0016 
 
Multi point 
adj. Mode 
MSET0000 
 
WBI20255 
Point 2 
WBI20229 
MG2G**** 
MG2B**** 
MG2R**** 
 
 
 
 
 
  Point 1 
WBI10040 
MG1G**** 
MG1B**** 
MG1R**** 
 
Write 
MSET0003 
 
Set 
Max.Level 
MGMG**** 
 
Initial setting 
 
 
 
Panel Contrast 
R/G/B_MAX 
R/G/B_HIGH 
R/G/B_LOW 
 
C
nt 
= 4000:1
 
WB
MAX 
= 4080
 
WB
H
= 3664/4080
 
WB
L
= 640/4080
 
 
(1)  Measurement     MAX Brightness
(2)  Set              MIN Brightness
(3)  Measurement     HIGH Brightness 
(4)  Measurement     LOW Brightness 
 
(5)  Calculation       H γ 
(6)  Calculation       Lγ 
 
(7)  Calculation       HIGH luminance (γ=2.2) 
 
(8)  Calculation       Initial setting of 
R/G/B_HIGH 
 
(9)  Set              Initial setting of 
R/G/B_HIGH 
 
(10)  Original WB adjustment is performed (HIGH) 
Set the specified gradation for point 2, fix the 
most  
faint    colour to get reference value, 
adjust others 2 colours to minus adjustment   
for reference value of point 2. 
 
(11) Measurement     HIGH Brightness 
       (Set)    R_HIGH= G_HIGH 
           G_HIGH= G_HIGH 
           B_HIGH= G_HIGH 
 
(12) Calculation       MAX luminance after WB   
           ADJ set to γ=2.2(L
XHG
) 
(13) Set           R/G/B_MAX 
 
(14) Calculation       LOW luminance (γ=2.2) 
 
(15) Calculation       Initial 
setting of 
R/G/B_LOW 
 
 
(16)  Set Initial setting of R/G/B_LOW 
 
(17) Original WB adjustment is performed (LOW). 
Adjust RB to the reference value of point 1. 
 
 
L
max
=305.7 cd/m² 
L
min
= L
max
/C
nt
 = 0.102 
L
XH
=235.1 cd/m² 
L
XL
=2.06 cd/m² 
 
Hγ=LOG((L
XH
-L
min
)/(L
max
-L
min
))/LOG(WB
H
/WB
MAX
)= 2.44
Lγ =LOG((L
XL
-L
min
) /(L
max
-L
min
))/LOG(WB
L
/WB
MAX
)=2.73  
 
L
H22
=(L
max
-L
min
) x (WB
H
/WB
MAX
)^2.2+L
min
=241.31 
 
WB
HX
=WB
MAX
 X ((L
H22
-L
min
)/(L
max
-L
min
))^(1/H γ)=3703 
 
R_HIGH=WB
HX
ʼ=3703 
G_HIGH=WB
HX
ʼ=3703 
B_HIGH=WB
HX
ʼ=3703 
 
R_HIGH=3702  
G_HIGH=3641 
B_HIGH=3703 
 
 
R_HIGH=3641  
G_HIGH=3641      
L
XHG
=
231.3
 
B_HIGH=3641 
 
L
XMX
=L
XHG
/((W
B
H
/WB
MAX
)^2.2)=293.04 
 
R_MAX=G_MAX*(R_HIG
H/G_HIGH)=4078 
G_MAX=WB
MAX
 X ((L
XMX
-L
min
)/(L
max
-L
min
))^(1/Hγ)=4010 
B_MAX=G_MAX*(B_HIGH/G_HIGH)=4078 
 
L
XLX
=(L
XMX
-L
min
) x (WB
L
/WB
MAX
)^2.2+L
min
=5.08 
WB
LX
=WB
MAX 
X ((L
XLX
-L
min
)/(L
max
-L
min
))^(1/Lγ)=901 
 
 
 
R_LOW=WB
XLX
=901 
G_LOW=WB
XLX
=901 
B_LOW=WB
XLX
=901 
 
R_LOW= 921 
G_LOW=901 
Example for adjustment method   
(be careful of INT setting) 
RESULT