FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES
Function
NO
Description Detection 
time
Restart 
condition
Restart 
times
Indoor Outdoor
Operation Self diagnostic
display
1
2
3
4
5
6
Indoor fan
lock
Indoor fan
rpm error
Indoor
freezing
guard
Indoor
overheating
control
DC
overcurrent
or overheat of
the IPM
AC
overcurrent
Compressor
lock
Stops operation if no revolution pulse
signal is input from the indoor fan motor for
one minute.
Stops operation if the revolution pulse
signal from the indoor fan indicates low
rpm (approximately 300 rpm or less).
Lowers the operating frequency if the
temperature of the indoor heat exchanger
goes below 5°C during cooling. Stops the
compressor if the temperature stays below
0°C for 4 minutes.
Lowers the operating frequency if the
temperature of the indoor heat exchanger
rises above the overheating temperature
during heating. Stops the compressor if the
temperature stays above the overheating
temperature for 1 minute at minimum
frequency.
Set values for overheating temperature
During normal operation: 51°C to 54°C
During full power operation: 54°C to
58°C
Stops the compressor if a current of
approximately 30 A or more flows in the
power transistor module. Also stops the
compressor if the temperature of the
power transistor module is exceeds 105°C.
Lowers the operating frequency if the
compressor AC current exceeds 
Peak control level 
[11.3A(heating), 10.4A(cooling)] 
Stops the compressor if the current
exceeds peak control level at 40 Hz or less.
Stops the compressor if the compressor
AC current exceeds 15 A.
Stops the compressor if the compressor
AC current exceeds 4.25 A immediately
after activating the compressor (at 17 to 30
Hz).
When indoor
fan is revolving
During cooling
and dry 
During heating
During
compressor
operation
During
compressor
operation
Immediately
after
compressor
activation.
Operation OFF
Automatically
restarts when the
exchange
temperature rises
above the freezing
prevention
temperature (above
2°C)
Automatically
restarts when the
exchange
temperature goes
below the
overheating
temperature.
Automatically
restarts after safety
time (170 seconds) 
Automatically
restarts after safety
time (170 seconds)
Automatically
restarts after safety
time (170 seconds)
No limit
No limit
No limit
4 times
4 times
4 times
Yes
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes