EasyManuals Logo

Sharp AE-X13BE Service Manual

Sharp AE-X13BE
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
33
AY-XP08/10/13CE
AE-X08/10BE-C
AE-X13BE
PERFORMANCE CURVES
NOTE: 1) Indoor fan speed: Hi
2) Vertical adjustment louver "45˚", Horizontal adjustment louver "front"
3) Indoor air temp. : Cooling 27˚C, Heating 20˚C
Figure P-1. At Cooling for AY-XP08CE
Figure P-2. At Cooling for AY-XP10CE
Figure P-3. At Cooling for AY-XP13CE
Figure P-4. At Heating for AY-XP08CE
Figure P-5. At Heating for AY-XP10CE
Figure P-6. At Heating for AY-XP13CE
25 30 35 40
2.0
2.2
2.4
2.6
10
12
14
600
700
800
900
Cooling capacity(kW)
Outside air temp.(˚C)
Input(W)
Outlet air temp.(˚C)
(Running frequency: 49Hz)
25 30 35 40
2.4
2.6
2.8
3.0
3.2
12
14
16
700
800
900
1000
(Running frequency: 62Hz)
Cooling capacity(kW)
Outside air temp.(˚C)
Input(W)
Outlet air temp.(˚C)
25 30 35 40
3.2
3.4
3.6
3.8
4.0
10
12
14
1000
1100
1200
1300
(Running frequency: 79Hz)
Cooling capacity(kW)
Outside air temp.(˚C)
Input(W)
Outlet air temp.(˚C)
-5 0 7510
2.4
2.8
3.2
3.6
35
40
45
700
800
900
1000
(Running frequency: 63Hz)
Heating capacity(kW)
Outside air tem
p
.
(
˚C
)
Input(W)
Outlet air temp.(˚C)
-5 0 5 7 10
2.5
3.0
3.5
4.0
30
35
40
45
800
900
1000
1100
(Running frequency: 74Hz)
Heating capacity(kW)
Outside air temp.(˚C)
Input(W)
Outlet air temp.(˚C)
-5 0 5 7 10
3.0
3.5
4.0
4.5
5.0
5.5
30
35
40
45
1200
1300
1400
1500
1600
(Running frequency: 95Hz)
Heating capacity(kW)
Outside air temp.(˚C)
Input(W)
Outlet air temp.(˚C)

Other manuals for Sharp AE-X13BE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp AE-X13BE and is the answer not in the manual?

Sharp AE-X13BE Specifications

General IconGeneral
BrandSharp
ModelAE-X13BE
CategoryAir Conditioner
LanguageEnglish

Related product manuals