5 – 4
20)How to disassemble the control box assembly
1.Cut the wire fixing band.(3 points)
2. Remove the 4 screws fixing the PWB.
3. Unlock the spacer's lock.
Instal this SHORT-CIRCUIT CONNECTOR
in a new CONTROL PWB at CONTROL PWB exchange.