EasyManua.ls Logo

Sharp AE-XM24HR - Chapter 5. Disassembling Procedure; Outdoor Unit

Sharp AE-XM24HR
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AEXM24HR
5 – 1
AEXM24HR
Service Manual
CHAPTER 5. DISASSEMBLING PROCEDURE
[1] OUTDOOR UNIT
1) Remove the 5 screws fixing the front panel R and slide
the front panel R down.
2) Remove the 10 screws fixing the top cover.
3) Remove the 6 screws fixing thefront panel L.
4) Remove the 6 screws fixing the rear guard.
5) Remove the 11 screws fixing the side cover R.
6) Remove the 6 screws fixing the side cabinet L.
7) Cut the insulators.
8) Remove the 2 screws fixing the control box cover.
Caution: Discharge electrytic capacitor before
touching this capacitor or other components or wirings.
Screws
Cut

Related product manuals