[2] TEST MODE
1. AH-G13
Keep pushing the "AUX." buttons and supply the power, the system will go to the test mode. In this mode, the output of operation is switched by
pushing the ""AUX." button in the unit or the "OI" button in the remote controller. Normal outputs are shown in Table.
STEP No.
OUTPUT "-" : NO CHECK, "O" : ON, "X" : OFF
BUZZER
FAN
MOTOR
LOUVER COMP.
LED 101 LED 102 LED 103
LED 104
RED YELLOW GREEN
BLUE
STEP0
BEEP2
O *1O*2O
X
XXX
*1 : 7°C<(ROOM TEMP.)<42°C
*2 : -2
°C<(PIPE TEMP.)<45°C
STEP1
BEEP1
X X O
X
O OPEN O
STEP2
BEEP1
O X O
X
O X X
STEP3
BEEP1
O X
X
O X X
STEP4
BEEP1
O O O
X
O X X
STEP5
BEEP1
OOO
X
OXX
STEP6
BEEP1
X X O
X
O X X
STEP7
BEEP1
XXX
X
OXX
STEP8
BEEP1
XXO
X
OXX
STEP9
BEEP1
O X O
X
O X X
STEP10
BEEP1
O O O
X
X CLOSE X
1. AH-PG15
STEP No. OUTPUT "-" : NO CHECK, "O" : ON, "X" : OFF
BUZZER
FAN
MOTOR
LOUVER COMP. PLASMA
CLUSTER
LED 101 LED 102 LED 103
LED 104
RED YELLOW GREEN
BLUE
STEP0
BEEP2
O *1O*2O
O
XXXX
*1 : 7°C<(ROOM TEMP.)<42°C
*2 : -2
°C<(PIPE TEMP.)<45°C
STEP1
BEEP1
X O
X
O OPEN O X
STEP2
BEEP1
O O O
O
OXXO
STEP3
BEEP1
O X
X
O X X O
STEP4
BEEP1
O O O
X
OXXX
STEP5BEEP1 X O O X OXXX
STEP6
BEEP1
X
O
X
OXXX
STEP7
BEEP1
X
X
OXXX
STEP8
BEEP1
X O
X
OXXX
STEP9
BEEP1
X O
X
OXXX
STEP10
BEEP1
O O O
X
X CLOSE X X
12
O
O
O
O
O
O
X
X