EasyManuals Logo

Sharp AH-G13 User Manual

Sharp AH-G13
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
CHAPTER 1. PRODUCT SPECIFICATION
[1] SPECIFICATION
1. AH-G13 / AU-G13
ITEMS
INDOOR UNIT
OUTDOOR UNIT
AH-G13
AU-G13
Cooling capacity kW 3.50
Moisture removal Liters/h
Electrical data
Phase Single
Rated frequency Hz
Rated voltage V 220
Rated current
A
4.95
Rated input * W 1045
Power factor % 97 - 99
Compressor Type Hermetically sealed rotary type
Oil charge
Refrigerant system Evaporator Slit fin and Grooved tube type
Condenser Slit fin and Grooved tube type
Control Capillary tube
Refrigerant volume
840g
Noise level
High
dB(A)
39
48
Mid.
dB(A)
33
Low
dB(A)
29
Fan s
y
stem
Drive Direct drive
Air flow quantity
High
m3
/
min.
10.2
27
Mid.
m3
/
min.
9.6
Low
m3
/
min.
8.7
Fan
Cross flow fan
Propeller fan
Connections
Refri
g
erant cou
p
lin
g
Flare t
yp
e
Refri
g
erant tube size Gas, Li
q
uid 3
/
8" , 1
/
4"
Drain piping
mm O.D 18
Others
Safety device Compressor : Overload protector
Fan motor : Thermal fuse / Protector
Fuse, Micro computer control
Air filters Polypropylene net (Washable)
Net dimensions
Width
mm
790
730
Height
mm
278
540
Depth
Net weight
mm
kg
198
10
250
34
1
φ
QJ208PHA
Model
50
(SUNISO 4GSI) or (NM56M) 410cc

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp AH-G13 and is the answer not in the manual?

Sharp AH-G13 Specifications

General IconGeneral
BrandSharp
ModelAH-G13
CategoryAir Conditioner
LanguageEnglish

Related product manuals