E-14
NOTES ON LOCATIONS 
INDOOR UNIT
1. Keep the air outlet clear of any obstacle so that outgoing air flows smoothly in the entire room.
2. Make a drain hose hole for easy drainage.
3. Provide sufficient space on both sides and above the unit.
4. The air filters should be easily taken in and out.
5. Keep TV set, radio and the like 1 m or more away from the unit and the remote control. 
6. Keep the air inlet clear of obstacles that could block incoming air.
7. The remote control may not function properly in a room equipped with an electronic simultane-
ous-start or rapid-start fluorescent lighting.  
8. Select a location that does not cause loud operation noise and extreme vibrations.
OUTDOOR UNIT
1. Place the outdoor unit on a stable base.
2. Provided sufficient space around the unit. It should also be well ventilated.
3. The unit should not be exposed to strong wind nor splashed with rain water. 
4. Water drain from the unit should be let out without problem. Lay a drain hose if required. In cold 
regions, installation of the drain pipe is not advisable as freezing could result.  
5. Keep TV set, radio and the like 1 m or more away from the unit.
6. Avoid locations exposed to machine oil vapor, salty air (facing the seashore, for example), hot 
spring vapor sulfur gas, etc. Such location can cause breakdown. 
7. Avoid locations exposed to muddy water (along a road, for example) or where the unit can be 
tampered with. 
8. Select a location where the outgoing air or operating noise cannot annoy others.
9. Keep the air outlet opening free of any obstacle. This could affect the performance of the unit 
and create loud noises.
INSTALLATION DIAGRAM 
Provide as much installation space as possible for efficient air-conditioning.
50 mm or more
50 mm 
or more
50 mm 
or more
70 mm or more
Coating tape 
(Commercially 
available)
50 mm or more
200 mm 
or more
100 mm 
or more
200 mm 
or more
Fix the remote control holder to the wall 
with the short screws.
4
 
REMOTE CONTROL HOLDER 
SHORT SCREW 
2
 
REMOTE CONTROL 
Coating tape (Commercially available)
50 mm or more
50 mm 
or more
70 mm or more
50 mm 
or more
300 mm 
or more
1000 mm 
or more
400 mm 
or more
9000/12000 BTU 24000 BTU 18000 BTU
300 mm or more
400 mm 
or more
300 mm 
or more
1000 mm  
or more
300 mm 
or more