AL-2020/2035/2040/2050/2060 SIMULATION, TROUBLE CODES 10 - 17
43 05 Fusing temperature setup in
duplex copy
[Function]
In the case of duplex copy, the shift temperature set with this simulation is applied to the fusing
temperature.
When this simulation is executed, the current set code number is displayed.
Enter the desired code number and press [OK]/[START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
14 Fusing start temperature
setting
[Function]
When this simulation is started, the currently set code number is displayed.
Press [ ] [ ] key (or [Numeric] key or [ ] [ ] key for the AL-2050/2060) to switch the set-
ting, and press [OK]/[START] key to save it to the EEPROM. The machine goes to the sub code
entry standby mode.
[Operation]
The operation is similar to simulation 43-01.
Main
code
Sub
code
Contents Details of function/operation
Code Shift temperature (°C) Remark
0Default
1–8
2–6
3–4
4–2
0
6+2
7+4
8+6
9+8
Code Set temperature (°C) Remark
0 160
1 165
2 170
3 175
4 180
5 185
6 190
7 195 Default
8 200
9 205
10 210