AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 48
If the simulation is executed with the RSPF unit closed, an error will
result.
Operation/procedure
1. Select the print item with the 10-key.
2. Press the [START] key.
The display is shifted to the copy menu.
3. Select the paper feed tray and the print density.
4. Press the [START] key.
Copying is started.
During execution of the print test, the [CUSTOM SETTINGS] key and
the [INTERRUPTION] key are invalid.
* If the IMC board is not installed, the key inputs cannot be made.
Operation/Procedure
Press the keys displayed on the LCD sequentially.
Adjust the touch panel coordinates.
When the point of “+” on the LCD is pressed, it turns gray. Press all the
four points of “+.
Operation/Procedure
Check the touch panel coordinates.
Press the keys displayed on the LCD sequentially.
When the touch panel is pressed, the X-coordinate and the Y-coordi-
nate (dot conversion values) are displayed.
Operation/procedure
Check the key input of the operation panel.
Press the keys displayed on the LCD sequentially.
After completion of all key entries, “COMPLETE” is displayed.
Operation/procedure
1. Enter the soft SW number to be selected with the 10-key.
2. Check and change the setting content of the selected soft SW.
3. Press the [START] key to save the set content.
The FAX-related soft SW is displayed on the LCD, and changing can
be made by monitoring it.
Note: Executable only when the FAX is installed.
64
64-1
Purpose Operation test/check
Function
(Purpose)
Used to check the operation of the printer function
(auto print operation).
Section Printer
Item Operation
Item Content
Setting
range
Default
1
2 BY 4
MODE
Self print is made in 2 by 4 mode
(printing 2 lines and not printing
4 lines). Since scanning is not
performed, when the original is
set on the RSPF, this cannot be
performed.
* Duplex print cannot be made.
1-2 1
2
LATTICE
PRINT
Lattice print (1cm, 1dot width
WLT, A3 print (A3 main scan,
WLT sub scan)) is performed.
* Duplex print can be made.
65
65-1
Purpose Adjustment
Function
(Purpose)
Used to adjust the touch panel (LCD display section)
detection position.
Section Operation (Display, Operation)
65-2
Purpose
Adjustment/Setting/Operation data output check
(Display, Print)
Function
(Purpose)
Used to check the touch panel (LCD display section)
detection position adjustment result.
Section Operation (Display, Operation)
65-5
Purpose
Adjustment/Setting/Operation data output check
(Display, Print)
Function
(Purpose)
Used to check the key inputs of the operation panel.
Section Operation (screen/operation)
66
66-1
Purpose Setting
Function
(Purpose)
Used to change and check the FAX-related soft SW.
Section FAX