AR-M350 SIMULATIONS 10-73
<This simulation is used only for production, and inhibited in the market.>
<Display message>
<Set values>
<Display message>
Main code 67
67-2
Purpose Operation test, check
Function (Content) Used to check the parallel I/F operation of the
printer.
(This simulation is made only in the production
site and not in the market.
It requires a special tool.)
Section Printer
Item Operation
Operation/Procedure The Centro port is checked.
1) Insert the adjustment jig into the Centro port
under the ready state, and press STRT.
2) The Centro port check is started.
3) If normal, OK is displayed. If abnormal,
the stage number where an error occurred
and NG are displayed.
WAITING Waiting
READY Check start OK
OK Check complete (normal)
STAGE*NG Check end (An error occurred in Stage *: 1-11)
67-11
Purpose Adjustment
Function (Content) Used to set Enable/Disable of the parallel I/F
select signal of the printer.
Section Printer
Item Operation
Operation/Procedure The select signal of Centro port is set.
Press START to set.
0OFF
1 ON (Initial value)
SIMULATION 67-2
CENTRO PORT CHECK .
CENTRO PORT:
READY
SIMULATION 67-2
CENTRO PORT CHECK .
CENTRO PORT:
OK STAGE7 NG(or
)
Press [CUSTOM SETTING] key.
Press [START] key
under the ready state.
SIMULATION 67-11
CENTRO SELECT IN SIGNAL SETTING. SELECT 0-1, AND PRESS START.
0. OFF
1. ON
0
67-16
Purpose Operation test, check
Function (Content) Used to check the operation of the network card.
Section Printer
Item Operation
Operation/Procedure The network card is checked.
CHECKING Checking
OK Check complete (Normal)
NG Check end (Abnormal)
SIMULATION 67-16
NETWORK INTERFACE CARD CHECK.
NIC: CHECKING
SIMULATION 67-16
NETWORK INTERFACE CARD CHECK.
NIC: OK (or NG)
Press [CUSTOM SETTING] key.
Check complete
!" #$%&'