AR-M350 SIMULATIONS 10-16
<List of set values>
7-8
Purpose Setup
Function (Content) Used to set Enable/Disable of warm-up time 
display. 
Section
Item Operation
Operation/Procedure The warm-up time is displayed in the unit of 
second. 
SIMULATION 7-8
WARM UP TIME DISPLAY.
ARE YOU SURE?
1. YES
2. NO
1
SIMULATION 7-8
WARM UP TIME DISPLAY. WARMING UP,PLEASE WAIT.
(UNIT:sec)
30
SIMULATION 7-8
WARM UP TIME DISPLAY. WARM UP COMPLETED.
(UNIT:sec)
60
Press [START] key to start measuring. Press [CUSTOM SETTING] key to stop.
Warm-up ends.
Press [CUSTOM SETTING] key.
Main code 8
8-1
Purpose Adjustment
Function (Content) Used to check and adjust the developing bias 
voltage in each print mode and its control circuit. 
Section Process 
(OPC drum, developing, transfer, cleaning)
Item
Operation/ProcedureEnter the output value to be adjusted with 
the 10 digit key pad. The current set value is 
highlighted at the right of each item. 
After entering the value with the 10-digit key 
pad press the START key. The output is made 
for 30 sec at the set value. 
Then the output is stopped.
Default Set range
1 Auto mode 485 0 ~745
2 Text mode
3 Text/Photo mode
4 Photo mode
5 Printer mode
6 Fax mode
7 Reverse developing bias voltage 150 0 ~255
1
SIMULATION 8-1
DV BIAS SETTING. INPUT VALUE, AND PRESS START.
1 : AUTO (0-745)
500
SIMULATION 8-1
DV BIAS SETTING. EXECUTING...
1 : AUTO
500
SIMULATION 8-1
DV BIAS SETTING. SELECT 1-7, AND PRESS START.
1.AUTO 500 2.CHARACTER 500
3.MIX 500 34.PHOTO 500
5.PRINTER 500 6.FAX 500 7.PLUS 500
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
 *       !"# $%&