AR-M350 SIMULATIONS 10-17
<List of set values>
<List of set values>
<List of set values>
8-2
Purpose Adjustment
Function (Content) Used to check and adjust the main charger grid 
voltage in each print mode and its control circuit. 
Section Process 
(OPC drum, developing, transfer, cleaning)
Item
Operation/Procedure Enter the output value to be adjusted with 
10 digit key pad. The current set value is 
highlighted at the right of each item. 
After entering the value with 10 digit key pad, 
press START key. 
The output is made for 30sec at the set value. 
Then the output is stopped.
Default Set range
1 Auto mode 645 200 ~ 900
2 Text mode
3 Text/Photo mode
4 Photo mode
5 Printer mode
6 Fax mode
8-6
Purpose Adjustment
Function (Content) Used to check and adjust the transfer charger 
current and its control circuit. 
Section Process 
(OPC drum, developing, transfer, cleaning)
Item
Operation/Procedure Enter the output value to be adjusted with 
10 digit key pad. The current set value is 
highlighted at the right of each item. 
After entering the value with 10 digit key pad, 
press START key. 
The output is made for 30sec at the set value. 
Then the output is stopped.
1
SIMULATION 8-2
MAIN GRID SETTING. INPUT VALUE, AND PRESS START.
1. AUTO (200-900)
500
SIMULATION 8-2
MAIN GRID SETTING. EXECUTING...
1 : AUTO
500
SIMULATION 8-2
MAIN GRID SETTING. SELECT 1- 6, AND PRESS START.
1. AUTO 500 2. CHARACTER 500
3. MIX 500 4. PHOTO 500
5. PRINTER 500 6. FAX 500
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
Default Set range
1 Cassette/manual paper feed 45PPM 267 0 ~ 620
35PPM 220
2 Paper feed from ADU 45PPM 310
35PPM 267
8-17
Purpose Operation test, check
Function (Content) Used to set and check the transfer roller output. 
Section Process 
(OPC drum, developing, transfer, cleaning)
Item Operation
Operation/Procedure Enter the output value to be adjusted with 
10 digit key pad. The current set value is 
highlighted at the right of each item. 
After entering the value with 10 digit key pad, 
press START key. 
The output is made for 30sec at the set value. 
Then the output is stopped.
Default Set range
1 SHV front surface 160(45PPM)
120(35PPM)
0 ~ 375
2 SHV back surface
3 THV-output 780 0 ~1250
1
SIMULATION 8-6
THV+SETTING. INPUT VALUE, AND PRESS START.
1. FRONT(0-620)
140
SIMULATION 8-6
THV+SETTING. EXECUTING...
1. FRONT
140
SIMULATION 8-6
THV+SETTING. SELECT 1-2, AND PRESS START.
1. FRONT 140
2. BACK 140
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
1
SIMULATION 8-17
TRANSFER ROLLER SETTING. INPUT VALUE, AND PRESS START.
1. FRONT (0-375)
500
SIMULATION 8-17
TRANSFER ROLLER SETTING. EXECUTING...
1. FRONT (0-375)
500
SIMULATION 8-17
TRANSFER ROLLER SETTING. SELECT 1-3, AND PRESS START.
1. SHV FRONT 500
2. SHV BACK 500
3. THV- 500
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
 +       !"# $%&