EasyManua.ls Logo

Sharp AR-M455U - Page 152

Sharp AR-M455U
276 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 16
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated.
Press [CUSTOM SETTINGS] key to stop the operation.
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played.
The active sensors and detectors are highlighted.
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated for 10sec.
Press [CUSTOM SETTINGS] key to stop the operation.
NOTE: Never execute this simulation with toner in the toner hop-
per.
If executed, excessive toner will enter the developing sec-
tion. Be sure to remove the toner motor from the toner hop-
per before execution.
Press [START] key. Press [CUSTOM SETTINGS] key.
Press [START] key. Press [CUSTOM SETTINGS] key.
Or after 30sec output.
9
9-1
Purpose Operation test/Check
Function
(Purpose)
Used to check and adjust the operation of the load
(clutch/solenoid) in the duplex section and the
control circuit.
Section Duplex
Item Operation
1 ADMEN1 ADU motor 1 control signal
2 ADMEN2 ADU motor 2 control signal
3 DGS ADU gate solenoid
Press [START] key. Press [CUSTOM SETTINGS] key to
stop the operations.
SIMULATION 8-17
1
TRANSFER ROLLER SETTING. SELECT 1-3, AND PRESS START.
1.SHV FRONT 160
2.SHV BACK 160
3.THV- 780
SIMULATION 8-17
TRANSFER ROLLER SETTING. INPUT VALUE, AND PRESS START.
1.FRONT (0-240)
160
SIMULATION 8-17
TRANSFER ROLLER SETTING. EXECUTING···.
1.FRONT(0-240)
160
SIMULATION 9-1
ADU OUTPUT CHECK. SELECT 1-3, AND PRESS START.
1.ADMEN1
2.ADMEN2
3.DGS
1
SIMULATION 9-1
ADU OUTPUT CHECK. EXECUTING···.
1.ADMEN1
2.ADMEN2
3.DGS
1
9-2
Purpose Operation test/Check
Function
(Purpose)
Used to check the operations of the sensors and
detectors in the duplex section and its control
circuit.
Section Duplex
Item Operation
ADUSET ADU installation detection
DSW_D ADU cabinet open detection
AINPD ADU paper entry detection
APOD ADU paper exit detection
APPD1 ADU paper detection 1
APPD2 ADU paper detection 2
10
10-1
Purpose Operation test/Check
Function
(Purpose)
Used to check the operations of the toner motor
and the related circuit.
Section Process (Developing)
Item Operation
1 Toner motor rotation start
2 Cancel (The display returns to the main code entry menu.)
Press [START] key. Press [CUSTOM SETTINGS] key to
stop the operations. Or after 10sec.
SIMULATION 9-2
ADU SENSOR CHECK.
ADUSET DSW_D AINPD APOD APPD1 APPD2
SIMULATION 10-1
TONER MOTOR ACTIVATION.
ARE YOU SURE?
1.YES
2.NO
2
SIMULATION 10-1
TONER MOTOR ACTIVATION. EXECUTING···.
1