E-12
The unit will turn off automatically according to your setting.
Timer duration can be set from a minimum half an hour (30 minutes) to a maximum
of 12 hours.
Up to 9.5 hours, you can set in half-hour (30-minute) increments, and from 10 to 12
hours, in 1-hour increments.
TIMER OPERATION
TIMER OFF
When the TIMER OFF is set, the temperature
setting is automatically adjusted to prevent
the room from becoming excessively cold
while you sleep. (Auto Sleep function)
COOL/DRY MODE:
One hour after the timer operation begins,
the temperature setting rises 1°C higher
than the original temperature setting.
HEAT MODE:
One hour after the timer operation begins,
the temperature setting drops 3°C lower
than the original temperature setting.
1
TO CANCEL TIMER
TIPS ABOUT TIMER OFF OPERATION
Point the remote control at the signal receiver win-
dow on the unit.
1
Press the TIMER OFF ( ) button and set
the time as desired.
The time setting will change as you press the
button as follows,
Hold the button down to speed through the
settings.
The orange TIMER lamp (
) on the unit
will light.
The unit will generate a beep when it re-
ceives the signal.
The time setting will count down to show the
remaining time.
Display shown when you
set the unit to ture off 2.5
hours later.
Press the CANCEL button.
The orange
TIMER lamp
(
) on the
unit will turn
off.
TO CHANGE TIMER SETTING
Press the TIMER button which you wish to
change, (TIMER OFF or TIMER ON) and
change the time setting.
0.5h 1.0h 1.5h 10h 11h 12h

Other manuals for Sharp AY-AP9FHR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp AY-AP9FHR and is the answer not in the manual?

Sharp AY-AP9FHR Specifications

General IconGeneral
AC input voltage220-240 V
AC input frequency50 Hz
Design load (cooling)- kW
Energy efficiency class (cooling)A
Annual energy consumption (cooling)410 kWh
Hourly energy consumption (cooling)3.8 kWh
Energy efficiency class (heating) (Warmer heating season)-
Annual energy consumption (heating) (Warmer heating season)- kWh
TypeSplit system
Multi-splitYes
Product colorWhite
Hose length (max)10 m
Refrigerating mediumR410A
Air conditioner functionsCooling, Heating
Cooling capacity in watts (nominal)820 W
Cooling energy efficiency (EER, W/W)3.21
Heating energy efficiency (COP, W/W)3.61
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)855 W
Indoor unit depth184 mm
Indoor unit width810 mm
Indoor unit height270 mm
Indoor unit weight9000 g
Indoor units quantity1
Indoor unit noise level (high speed)55 dB
Outdoor unit depth250 mm
Outdoor unit width730 mm
Outdoor unit height540 mm
Outdoor unit weight32000 g
Outdoor unit noise level61 dB