EasyManua.ls Logo

Sharp AY-AP9FHR User Manual

Sharp AY-AP9FHR
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
AY-AP7FHR
AY-AP9FHR
AY-AP12FHR
AY-AP7FHR
AY-AP9FHR
AY-AP12FHR
SPLIT TYPE
ROOM AIR CONDITIONER
OPERATION MANUAL
CONDIZIONATORE D’ARIA
DA CAMERA TIPO SPLIT
MANUALE DI ISTRUZIONI
AR CONDICIONADO DE SALA
DE DUAS UNIDADES
MANUAL DE OPERAÇÃO
ENGLISH
AE-A7FHR
AE-A9FHR
AE-A12FHR
*Plasmacluster is a trademark of
SHARP Corpration.
(AY-AP7FHR/AY-AP9FHR)
(AY-AP12FHR)
ITALIANO
PORTUGUÊS
INDOOR UNIT
UNITÀ INTERNA
UNIDADE INTERIOR
OUTDOOR UNIT
UNITÀ ESTERNA
UNIDADE EXTERIOR

Other manuals for Sharp AY-AP9FHR

Question and Answer IconNeed help?

Do you have a question about the Sharp AY-AP9FHR and is the answer not in the manual?

Sharp AY-AP9FHR Specifications

General IconGeneral
AC input voltage220-240 V
AC input frequency50 Hz
Design load (cooling)- kW
Energy efficiency class (cooling)A
Annual energy consumption (cooling)410 kWh
Hourly energy consumption (cooling)3.8 kWh
Energy efficiency class (heating) (Warmer heating season)-
Annual energy consumption (heating) (Warmer heating season)- kWh
TypeSplit system
Multi-splitYes
Product colorWhite
Hose length (max)10 m
Refrigerating mediumR410A
Air conditioner functionsCooling, Heating
Cooling capacity in watts (nominal)820 W
Cooling energy efficiency (EER, W/W)3.21
Heating energy efficiency (COP, W/W)3.61
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)855 W
Indoor unit depth184 mm
Indoor unit width810 mm
Indoor unit height270 mm
Indoor unit weight9000 g
Indoor units quantity1
Indoor unit noise level (high speed)55 dB
Outdoor unit depth250 mm
Outdoor unit width730 mm
Outdoor unit height540 mm
Outdoor unit weight32000 g
Outdoor unit noise level61 dB

Summary

Disposal Information

For Private Households in the EU

Disposal instructions for private households within the EU, emphasizing separate collection.

For Private Households Outside the EU

Disposal instructions for private households outside the EU, advising contact with local authorities.

For Business Users in the EU

Disposal guidance for business users in the EU, suggesting dealer contact and local facilities.

For Business Users Outside the EU

Disposal instructions for business users outside the EU, advising contact with local authorities.

Important Safety Instructions

Warnings for Use

Safety precautions for operating the air conditioner, covering power cord, air exposure, and grounding.

Warnings for Installation, Removal, and Repair

Safety warnings related to installing, removing, or repairing the unit, advising professional help.

Cautions for Use

Additional safety cautions for using the air conditioner, including ventilation and handling.

Cautions for Location and Installation

Safety cautions regarding the installation location and electrical setup for the air conditioner.

Additional Notes on Operation

Operating Temperature Range

Specifies the recommended indoor and outdoor temperature ranges for cooling and heating.

Power Failure Behavior

Explains how the unit behaves and what to do after a power failure occurs.

Heating Efficiency

Discusses factors affecting heating efficiency, like outside temperature and suggests using an additional heater.

Energy Saving Tips

Provides practical advice and tips for saving energy when using the air conditioner.

Part Names

Indoor Unit (AY-AP7FHR/AY-AP9FHR)

Identifies and labels the components of the indoor unit for specific models.

Outdoor Unit

Identifies and labels the components of the outdoor unit.

Indoor Unit (AY-AP12FHR)

Identifies and labels the components of the indoor unit for a specific model.

Remote Control Operation

Remote Control Overview

Details the buttons and display elements of the remote control.

Loading Batteries

Instructions on how to insert batteries into the remote control.

How to Use the Remote Control

Guidance on pointing the remote and ensuring signal reception.

Basic Operation

Selecting Operation Mode

Steps to select AUTO, HEAT, COOL, or DRY operation modes.

Setting Temperature

How to adjust the desired temperature for different operation modes.

Setting Fan Speed

How to select the desired fan speed for optimal air circulation.

Air Flow Direction Adjustment

Vertical Air Flow Direction

Instructions on adjusting the vertical louvre using the remote control.

Horizontal Air Flow Direction

Guidance on manually adjusting the horizontal louvre for air flow control.

Plasmacluster Operation

Activating Plasmacluster

How to turn on the Plasmacluster ion generator and what indicators to expect.

Cancelling Plasmacluster

Steps to turn off the Plasmacluster operation.

Special Operation Modes

Turbo Operation

How to activate Turbo mode for rapid cooling or heating and its limitations.

One-Hour Off Timer

How to set the unit to automatically turn off after one hour.

Timer Operations

Timer Off Function

How to set the unit to turn off automatically after a set duration.

Timer On Function

How to set the unit to turn on automatically at a specified time.

Auxiliary Mode

Using Auxiliary Mode

Instructions for operating the unit using the AUX button when the remote is unavailable.

Maintenance

Cleaning the Filters

Step-by-step guide for removing, cleaning, and reinstalling air filters.

Cleaning the Unit and Remote Control

Guidance on how to clean the main unit and the remote control safely.

Maintenance Before and After Season

Recommended maintenance tasks before and after the air conditioner season.

Before Calling for Service

Non-Malfunction Conditions

Lists conditions that do not indicate equipment malfunctions.

Troubleshooting Common Issues

Provides checks for common problems like unit failure to operate or cool/heat.

Remote Control Signal Issues

Troubleshooting steps for problems with the remote control signal reception.

Related product manuals