CONTROL BOX
1.Control unit box's Approach to decomposition.
1) Cut the band 4) Take off box cover.
2) Take off lead wires from terminal assembly. 5) Take off heat sink holder.
(Blue wire,Brown wire,Red wire,Green/Yellow wire)
6) Take off screws (8 PCS)
3) Take off screw (earth).
Take off earth lead wire (green/yellow) from terminal holder.
BAND
SCREW
BOX COVER
HEAT SINK HOLDER
AY-ZP35PR