– 13 –
CD-XP200W
Standard Specification of Stereo System Error Message Display Contents
Error Contents DISPLAY Notes
TAPE Mechanism Error. 'ER-TA**' 00: Tape Mechanism Error.
01: Initial Error.
CD Pickup Mechanism Error. 'ER-CD**' 01: PU-IN SW Detection NG.
CD Changer Mechanism Error. 'ER-CD**' 10: Changer Error.
(*) 11: Initial Error.
CD DSP Communication Error 'ER-CD**' 31: DSP COMMUNICATION ERROR
Focus Not Match. 'NO DISC'
IL Time Over. 'NOT READ'
TUN PLL Unlock. 'ER-TU**' 00: TUN Error.
01: PLL Unlock.
(*) CHECKING:
If CD changer mechanism error is detected, 'CHECKING' will be display instead of 'ER-CD**' display 'ER-CD**' will only be display
when CD changer mechanism error had been detected for the 5 th times.
Speaker abnormal detection and +B PROTECTION display
In case speaker abnormal detection or +B PROTECTION had occurred, it can be check by pressing 'POWER', 'VIDEO' and 'X-
BASS' key twice. Display will show "S** B**". S is referring to speaker abnormal detection and B is referring to +B PROTECTION.
** is in hex valve.
+B PROTECTION is condition when irregular process occur on power supply line.

Other manuals for Sharp CD-XP200W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp CD-XP200W and is the answer not in the manual?

Sharp CD-XP200W Specifications

General IconGeneral
BrandSharp
ModelCD-XP200W
CategoryStereo System
LanguageEnglish

Related product manuals