EasyManua.ls Logo

Sharp CV-P09FR - Water Drainage Procedures

Sharp CV-P09FR
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
DRAINAGE
Prepare for drainage and drain out water within the unit in the following cases.
If the unit stops operating and the TIMER (
), OPERATION ( ) and TURBO COOL ( )
lamps are blinking. (This indicates that the water tank inside the unit is full.)
1
Make sure to turn the unit off.
2
Turn the drainage nozzle to the OPEN
position.
3
Pull the stopcock out from the drainage
nozzle.
When the stopcock is removed, a small amount of
water may be discharged from the drainage nozzle.
4
Insert the hose clamp into a standard com-
mercially available hose (12.7 mm inner di-
ameter, 16.7 mm outer diameter).
5
Attach the hose to the drainage nozzle, and
secure it with the hose clamp.
Prepare for draining, as drain water will come out
through the hose during operation.
6
Press the AUX. button on the unit twice.
The water will drain out through the drainage hose.
Mximum amount of water that may be drained out
is approximately 2 liters.
The OPERATION, TIMER and TURBO COOL
lamps will be blinking.
7
When drainage water stops running out from the hose, turn the unit off by
pressing AUX. button.
This would take about one minute.
8
Remove the hose from the drainage nozzle, and replace the stopcock.
Keep the hose clamp in case of re-used.
9
Turn the drainage nozzle to the CLOSE position.
Whenever the unit is moved (to provent water within the unit from spilling).
When the unit is not used for a long time.
1
Carry out the above procedures from 1 to 5.
2
Press the AUX. button on the unit.
The water will drain out through the drainage hose.
Mximum amount of water that may be drained out is approximately 2 liters.
The OPERATION lamps will light.
3
When drainage water stops running out from the hose, turn the unit off by
pressing AUX. button.
This would take about one minute.
4
Remove the hose from the drainage nozzle, and replace the stopcock.
Keep the hose clamp in case of re-used.
5
Turn the drainage nozzle to the CLOSE position.
6
Remove the stopcock from the drainpipe nozzle, and completely drain any
water within the unit.
Always prepare a receptacle to collect the water
before draining. Mximum amount of water that may
be drained out is approximately 0.2 liters.
7
Replace the stopcock to the drainpipe nozzle.
E-17
Stopcock
Drainpipe nozzle
Drainage
nozzle
Stopcock
“OPEN position”
Hose clamp
Hose