10. TROUBLESHOOTING
FLOW CHART NO.6
The fluorescent display tube does not light.
No
Is 5V voltage supplied to the IC5001 pin 18? Check the AT 5V line.
Yes
No
Is -30V voltage supplied to the IC5001 pin 16?
Check the AT -30V line.
Yes
No
Is 4.0 MHz oscillation signal confirmed on the
IC5001 pins 19 and 20?
Check FL5001, IC5001 and their periphery.
Yes
No
Check the signal lines of FIP DA, FIP CK, FIP CS
of IC5001 and IC504.
Check or replace IC5001 and IC504.
FLOW CHART NO.7
The key operation is disabled.
No
Is key switch contact and installation state normal?
Replace Key switch.
Yes
Is the control voltage input normally into the pins
95 and 96 of IC504?
No
Check the power circuit and D5001.
No
Check for damages such as crack on the
fluorescent display tube.
Yes
Is the filament voltage supplied to both ends of
pins 1, 2 and 61, 62 of fluorescent display tube?
Yes
Check the fluorescent display tube and its periphery.
FLOW CHART NO.8
Shuttle ring doesn't function.
No
Is there a wrong point in the ring installation
condition of shuttle switch and the switch itself?
It meets a symptom, it copes, or, part exchange.
Yes
Is the control signal of 63 of IC504, 26 pin being
inputted normally? (63pinJ1,26pinJ2)
Shuttle ring rotation direction Shuttle control signal
Output wave shape
Clockwise direction J2~GND
J1~GND
Counterclockwise
direction
J2~GND
J1~GND
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
S8101
S8108
S8109
PLAY
S8103
STOP
STILL/PAUSE
KEY-1 KEY-2
OPEN/CLOSE