ER-A410/ER-A420 SERVICE (SRV) MODE
1 – 9
[JOB#918] ER-A410: MRS = 0000
ER-A420: MRS = 0000
#918-A: 1. Printing of text of a tied PLU in set PLU
2. Direct non-tendering finalization after previous tender enter
#918-B: Not used (Fixed at “0”)
#918-C: 1. Printing of Z1/Z2 counter in Z reports
#918-D: Not used (Fixed at “0”)
[JOB#919] ER-A410: MRS = 0000
ER-A420: MRS = 0000
#919-A: Not used (Fixed at “0”)
#919-B: 1. Checking of casher # on guest check when a reorder is
made
2. Guest check No.
#919-C: 1. PBLU entry
2. Amount printing when PLU unit price is 0
#919-D: 1. Conversion ST printing of native ST
[JOB#920] NOT USED ER-A410: MRS = 0000
ER-A420: MRS = 0000
[JOB#921] ER-A410: MRS = 0000
ER-A420: MRS = 0000
#921-A, B: Not used (Fixed at “00”)
#921-C: 1. Vat shift operation timing duaring at transaction
#921-D: Not used (Fixed at “0”)
[JOB#922] ER-A410: MRS = 0000
ER-A420: MRS = 0000
#922-A: Not used (Fixed “0”)
#922-B: 1. Jornal print after SLIP/GC.RCPT
#922-C, D: Not used (Fixed “00”)
[JOB#923] NOT USED ER-A410: MRS = 0000
ER-A420: MRS = 0000
[JOB#924] NOT USED ER-A410: MRS = 0000
ER-A420: MRS = 0000
[JOB#925] NOT USED ER-A410: MRS = 0000
ER-A420: MRS = 0000
[JOB#926] ER-A410: MRS = 0400
ER-A420: MRS = 0400
#926-A: Not used (Fixed at “0”)
#926-B: 1. Program reset at PGM2 mode
#926-C: Not used (Fixed at “0”)
#926-D: 1.Check VP
1. Printting of text of a
tied PLU in set PLU
2. Direct non-tendering
finalization after previ-
ous tender enter
918-A
YES
Disable 0 ★
Enable 2
NO
Disable 4
Enable 6
1. Printing of Z1/Z2 counter in Z reports 918-C
Yes 0 ★
No 4
1. Checking of casher #
on guest check when
a reorder is made
2. Guest check No.
919-B
YES
Auto generation 0 ★
Manual 1
NO
Auto generation 4
Manual 5
1. PBLU entry 2. Amount printing when
PLU unit price is 0
919-C
Non compulsory
No 0 ★
Yes 1
Compulsory
No 2
Yes 3
1. Conversion SBTL print of native SBTL 919-D
Yes 0 ★
No 4
1. Vat shift operation timing duaring at trans-
action
921-C
Only at the start of transaction 0
★
During a transaction 2
1. Jornal print after SLIP/GC.RCPT 922-B
NO 0
★
YES 2
1. Program reset at PGM2 mode 926-B
Disable 0
Enable 4 ★
1. Check VP 926-D
Normal 0 ★
CHEQUE EURO 2