E-19
ENGLISH
Model KC-D60E KC-D40E
Power supply 220 ~ 240 V 50/60 Hz
Fan Speed Adjustment
MAX MED LOW MAX MED LOW
CLEAN AIR
Fan Speed (m
3
/hour)
396 240 90 216 144 60
Rated Power (W)
80 24 5.5 25 12 5
Noise Level (dBA)
55 45 25 47 37 23
CLEAN AIR
& HUMIDIFY
Fan Speed (m
3
/hour)
366 240 90 180 144 60
Rated Power (W)
70 26 7 19 14 7
Noise Level (dBA)
54 45 25 43 37 23
Humidi cation (mL/hour)*1
660 480 230 440 370 190
Recommended Room Size (m
2
)*2 ~48 ~26
High density Plasmacluster ion recommended room size (m
2
)
*3 ~35 ~21
Water Tank Capacity (L) 3.0 2.5
Sensors
Dust/Odour/Temperature & Humidity Dust/Temperature & Humidity
Filter type
Dust collection HEPA with Microbial control *4
Deodorization Deodorizing
Cord Length (m) 2.0
Dimensions (mm) 420 (W) × 242 (D) × 637 (H) 399 (W) × 230 (D) × 615 (H)
Weight (kg) 8.6 7.9
*1 • Humidi cation Amount changes in accordance with indoor and outdoor temperature and humidity.
Humidi cation Amount increases as temperatures rise or humidity decreases.
Humidi cation Amount decreases as temperatures decrease or humidity rises.
Measurement Condition: 20 ºC, 30 % humidity (JEM1426)
*2 • The Recommended Room Size is appropriate for operating the unit of maximum fan speed.
The Recommended Room Size area indicates the space where a certain amount of dust particles can be removed in 30 minutes.
*3
Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the center of the room (at a height of approximately 1.2 meters from the
oor) when the product is placed next to a wall and run at the MED operation position.
*4
The lter removes more than 99.97% of particles of 0.3-micron dust. (JEM1467)
Standby Power
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this
product consumes about 0.9 W of standby power.
For energy conservation, unplug the power cord when the unit is not in use.
SPECIFICATIONS
KC-D60 40E_EN (MA+CS).indd Sec1:19KC-D60 40E_EN (MA+CS).indd Sec1:19 10/29/13 5:15 PM10/29/13 5:15 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp KC-D60E and is the answer not in the manual?

Sharp KC-D60E Specifications

General IconGeneral
BrandSharp
ModelKC-D60E
CategoryAir Cleaner
LanguageEnglish

Related product manuals