INSPECTION AFTER REPAIRING
1. Switch cook should be at the center of panel.
2. Ensure that there is no any contaminants, deposits, stains exist on heater plate, thermostat and outside
bottom of inner pot.
3. Firmly put inner pot inside the cooker, move inner pot right and left to ensure it can be closely contact
with outer pot.
4. Check the operation of switch cook and thermostat.
- When inner pot is already put in, little bit right and left moveable, push switch cook, the state of
switch cook must be steadily pushed down, as soon as the inner pot is lifted up, switch cook will
automatically spring up.
5. Check the operation of indicator lamp and switch cook connection.
5.1 Plug inlet into a socket pin.
5.2 Check the state of indicator lamp when push switch “COOK” and “WARM”.
5.3 Put the inner pot into the cooker, push switch cook. Ensure that the inner pot can be firmly
contacted with the heater plate.
3. Ensure the capability of up-down movement of switch lever.
2. As soon as inner pot is lifted up from outer pot, switch lever must be spring up and micro switch is
pressed completely. This rice cooker is so designed that the cooking switch will not be put in “COOK”
position whenever the inner pot is taken off or not set into the cooker before use.
(Micro SW. is open position)
Thermostat Ass’y
No Gap
Gap
Heater Plate
SW. Angle
No gap
(Thermo plate touch reflector)
Reflector
Switch Cook Spring Back
SW. Lever
Micro Switch