TESTING OPERATING CONDITION
(1) Simplified Testing Method
1. Firmly put inner pot into the cooker, and also close the lid.
2. Plug the power cord.
3. Push switch cook to check the operation of thermostat. It will cut off approximately in 3-5 minutes,
which is the standard timing.
(2) Water Boiling Method
1. Fill 2 measuring cups of water in the inner pot.
2. Firmly put inner pot into the outer pot.
3. Plug the power cord.
4. Push switch cook.
5. As soon as water evaporated dry, thermostat must cut off.
(3) Rice-Cooking Method
1. Fill rice and water at the maximum level of the inner pot.
2. Plug the power cord, and push switch cook.
3. After rice is already cooked and warm for 15 minutes further, check whether the rice is completely
cooked.
4. Turn over the inner pot, check the cooked rice at the bottom of inner pot. If its overdone layer is slightly
light drown, the cooking operation is acceptable. In contrary, if cooked rice is brownish of uncompletely
cooked, thermostat may be fault.