32
LC-13SH1E
LC-15SH1E
VOLTAGE MEASUREMENT CONDITION:
1. The voltages at test points are measured on the
stable supply voltage of AC 220–240V. Signals are
fed by a colour bar signal generator for servicing
purpose and the above voltages are measured with
a 20k ohm/V tester.
INDICATION OF RESISTOR & CAPACI-
TOR:
RESISTOR
1. The unit of resistance “” is omitted.
(K=k=1000 , M=M).
2. All resistors are ± 5%, unless otherwise noted.
(J= ± 5%, F= ± 1%, D= ± 0.5%)
3. All resistors are 1/16W, unless otherwise noted.
4. All resistors are Carbon type, unless otherwise
noted.
C
: Solid
W
: Cement
S
: Oxide Film
T
: Special
N
: Metal Coating
CAPACITOR
1. All capacitors are µF, unless otherwise noted.
(P=pF=µµF).
2. All capacitors are 50V, unless otherwise noted.
3. All capacitors are Ceramic type, unless otherwise
noted.
(ML): Mylar (TA): Tantalum
(PF): Polypro Film (ST): Styrol
CAUTION:
This circuit diagram is original one, therefore there may be a
slight difference from yours.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH “
å
( ) ARE
IMPORTANT FOR MAINTAINING THE SAFETY OF
THE SET. BE SURE TO REPLACE THESE PARTS
WITH SPECIFIED ONES FOR MAINTAINING THE
SAFETY AND PERFORMANCE OF THE SET.
DESCRIPTION OF SCHEMATIC DIAGRAM

Other manuals for Sharp LC-13SH1E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp LC-13SH1E and is the answer not in the manual?

Sharp LC-13SH1E Specifications

General IconGeneral
BrandSharp
ModelLC-13SH1E
CategoryLCD TV
LanguageEnglish

Related product manuals