MD-E9000H
ā 18 ā
CD PLAY B2 Servo adjustment mode
NORMAL EDIT B4 Recording mode
HIGH EDIT F2 Other mode
MD REC A8 Menu change at each mode
MD PLAY A2 Menu access
MD STOP A7 Menu stop
SKIP UP AA Slide to outer
SKIP DOWN AC Slide to inner
VOLUME UP F3 Adjustment value +1
VOLUME DOWN F4 Adjustment value -1
CD STOP F5 Display change
ON/STAND-BY 1F+D1 MD test mode
LOAD-SW ON B5 Access loading operation
MD EJECT B3 Eject operation
3. MD test mode
a. Communication start after proceed MD reset process
b. Power ON at MD function
c. Transmit command correspond to each button during button input (min 5 transmission)
Display: Display all 10 characters which transmitting from text area by MD command
d. Eject and loading is same as normal operation
e. Change to MD non adjustment mode by ON/STAND-BY button
f. MD no adjustment mode is like procedure below
1) Transmit power off command (1F) to MD
2) Wait until function bit: 00 (POWER OFF) confirmation
3) MD micom reset
4) Transmit non automatic adjustment test mode command (D1) until change to MD mode (E0) after communication start
5) Display 1, 3, 5, 7 segment according to music calender data when MD mode E0
6) Normal operation for next step
Reference
To cancel non automatic adjustment mode, need to do either reset or power failure MD micom will start normal mode operation
if not receive non adjustment mode command when recover from power failure.
Button Name
Function
Button and command when MD TEST mode
Command
High (double) speed mode
It is possible to change between high speed/normal speed by pressing HIGH EDIT/NORMAL EDIT button during stop.
"HIGH" mark will light up when high speed mode.
Actual operation is just only sending 1 time/2 time speed operation command other is same with normal speed.
When change from high speed to normal speed, it will set normal speed parameter and RF amp.