MX-3610N SIMULATION 5 – 21
9
9-2
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the sen-
sors and detectors in the paper reverse
section (duplex section) and its control cir-
cuit.
Section
Duplex
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played.
The code names of the sensors and the detectors which are active
are highlighted.
9-3
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the load in
the paper reverse section (duplex section)
and its control circuit.
Section
Duplex
Operation/Procedure
1) Select the item to be operation checked with the touch panel
key.
2) Press [EXECUTE] key.
The selected load performs the operation.
When [EXECUTE] key is pressed, the operation is terminated.
18cpm/20cpm/23cpm/26cpm/31cpm machine
*1: Displayed, but not installed in some models.
36cpm machine
*: Not used, but the button is displayed.
10
10-1
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the toner
supply mechanism (toner motor) and the
related circuit.
Section
Process (Developing)
Operation/Procedure
1) Select a target of the operation check with the touch panel key.
When [ALL] key is pressed, all the items are selected.
2) Press [EXECUTE] key.
The selected load operation is performed for 10 sec.
When [EXECUTE] key is pressed, the operation is terminated.
This simulation must be executed without installing the toner car-
tridges.
If this simulation is executed with the toner cartridges installed,
toner will be forcibly supplied to the developing unit, resulting in
overtoner.
If this simulation is erroneously executed with the toner cartridges
installed, overtoner state may be deleted by making a few black
background copy in the single color copy mode of the target color.
13
13--
Purpose
Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag "U1" trouble.
Section
Operation/Procedure
1) Press [EXECUTE] key.
2) Press [YES] key to execute cancellation of the trouble.
14
14--
Purpose
Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag H3, H4, H5
troubles.
Section
Operation/Procedure
1) Press [EXECUTE] key.
2) Press [YES] key to execute cancellation of the trouble.
15
15--
Purpose
Clear/Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag "U6" trouble.
Section
LCC
Operation/Procedure
1) Press [EXECUTE] key.
2) Press [YES] key to execute cancellation of the trouble.
APPD1 ADU paper transport detector 1
APPD2 ADU paper transport detector 2
DSW_ADU ADU paper guide open/close detector
Display Content
ADUM ADU motor
ADUC1 ADU transport clutch 1 *
1
Display Content
ADUC1 ADU transport clutch 1 (*)
ADUM ADU motor
ADUGS ADU gate solenoid
TNM_K Toner motor K
TNM_C Toner motor C
TNM_M Toner motor M
TNM_Y Toner motor Y