MX-2300G/N, MX-2700G/N 1 – 6
4) Rotate the belt by amount 10 cm to move the application part
to the surface.
* Till the applied powder reaches the cleaner installation loca-
tion.
5) Mount the cleaner frame UN on the primary transfer UN.
6) Apply titanium hydroxide to the belt.
* Apply titanium hydroxide to the belt 40 times (10 times in lat-
itudinal direction x 4 times in longitudinal direction) for
4 faces (making two circuits of the belt).
* Repeat half-around application and half-around rotation
each 4 times.
* Apply titanium hydroxide not to produce bias.
(Application amount)
7) Face the primary transfer UN upward.
* Face the primary transfer UN UPward from the cleaner UN
side.
* Take care that powders will not fly apart.
8) Mount the primary transfer UN on the machine and execute
simulation 25-1 (3-minute belt idling) once.
9) Check omissions in characters, and if many omissions are
found, execute simulation 25-1 once again.
10) If titanium hydroxide flies apart near the resist roller, clean it.
6
Little Moderate
amount
Much
Cleaner UN
: Oct. 13 2006
6