MX-C250  SIMULATION  6 – 19
 
26
 
26-6
Purpose
Setting
Function (Purpose)
Used to set the specifications (paper, fixed
magnification ratio, etc.) of the destination.
Section
Operation/Procedure
1) Select an item to be set with 10 keys.
2) Press [OK]/[START] key.
The selected set content is saved.
 
26-18
Purpose
Setting
Function (Purpose)
Used to set Disable/Enable of the toner
save mode operation. 
(For the Japan and the UK versions.)
Section
Operation/Procedure
1) Select an item to be set with 10 keys.
2) Press [OK]/[START] key.
The selected set content is saved.
K
TN_EMP_W
The threshold of toner empty (Over 
W count detection counts continu-
ously)
0255
TN_EMP_X
The threshold of toner empty (Over 
X count detection counts continu-
ously)
0255
TN_EMP_Y
The threshold of toner empty (Over 
Y count detection counts continu-
ously)
0255
C
TCS_B_AVE
.
Toner sensor output block average 
value
0255
TSG_HUM
Current TSG environment correction 
value (middle speed)
-
127
127
TSG_COV
Current TSG print rate correction 
value (middle speed)
-
127
127
TSG_LIFE
Current TSG developer life correc-
tion value (middle speed)
-
127
127
TSG_ENV
Current TSG cumulative drive area 
correction value (middle speed)
-
127
127
DELTA_TSG Average coverage area
-
254
254
DELTA_TSG Operation voltage correction value 1 255
TSG_TOTAL
Operation voltage target value (Mid-
dle speed)
0255
TCS_AVE. Toner sensor output average value 0 255
TN_EMP_W
The threshold of toner empty (Over 
W count detection counts continu-
ously)
0255
TN_EMP_X
The threshold of toner empty (Over 
X count detection counts continu-
ously)
0255
TN_EMP_Y
The threshold of toner empty (Over 
Y count detection counts continu-
ously)
0255
M
TCS_B_AVE
.
Toner sensor output block average 
value
0255
TSG_HUM
Current TSG environment correction 
value (middle speed)
-
127
127
TSG_COV
Current TSG print rate correction 
value (middle speed)
-
127
127
TSG_LIFE
Current TSG developer life correc-
tion value (middle speed)
-
127
127
TSG_ENV
Current TSG cumulative drive area 
correction value (middle speed)
-
127
127
DELTA_TSG Average coverage area
-
254
254
DELTA_TSG Operation voltage correction value 1 255
TSG_TOTAL
Operation voltage target value (Mid-
dle speed)
0255
TCS_AVE. Toner sensor output average value 0 255
TN_EMP_W
The threshold of toner empty (Over 
W count detection counts continu-
ously)
0255
TN_EMP_X
The threshold of toner empty (Over 
X count detection counts continu-
ously)
0255
TN_EMP_Y
The threshold of toner empty (Over 
Y count detection counts continu-
ously)
0255
Y
TCS_B_AVE
.
Toner sensor output block average 
value
0 255
TSG_HUM
Current TSG environment correction 
value (middle speed)
-
127
127
TSG_COV
Current TSG print rate correction 
value (middle speed)
-
127
127
TSG_LIFE
Current TSG developer life correc-
tion value (middle speed)
-
127
127
TSG_ENV
Current TSG cumulative drive area 
correction value (middle speed)
-
127
127
DELTA_TSG Average coverage area
-
254
254
DELTA_TSG Operation voltage correction value 1 255
TSG_TOTAL
Operation voltage target value (Mid-
dle speed)
0 255
TCS_AVE. Toner sensor output average value 0 255
TN_EMP_W
The threshold of toner empty (Over 
W count detection counts continu-
ously)
0 255
TN_EMP_X
The threshold of toner empty (Over 
X count detection counts continu-
ously)
0 255
TN_EMP_Y
The threshold of toner empty (Over 
Y count detection counts continu-
ously)
0 255
Item Display Contents
1 U.S.A. United States of America
2 CANADA Canada
3 INCH Inch series, other destinations
4 JAPAN Japan
5 AB_B AB series (B5 detection), other destinations
6 EUROPE Europe
7 U.K. United Kingdom
8 AUS. Australia
9 AB_A AB series (A5 detection), other destinations
10 CHINA China
Item Display Content
Default 
value
1COPY
0 Copy toner save mode is inhibited.
0
1 Copy toner save mode is allowed
2 PRINT
0
Printer toner save mode is inhib-
ited.
0
1
Printer toner save mode is 
allowed.