Loading...
5028
150 and 160 errors
150 and 160 error messages
Diagnostics and troubleshooting
215
Error code
Description
Action
150.80
The motor (duplex/MPF) did not turn on.
See
“Motor (duplex/MPF) service check” on
page 216
.
160.80
The motor (duplex/MPF) did not turn on.
150.81
The motor (duplex/MPF) did not turn off.
160.81
The motor (duplex/MPF) did not turn off.
150.82
The motor (duplex/MPF) speed did not ramp up to
the required level.
160.82
The motor (duplex/MPF) speed did not ramp up to
the required level.
150.83
The motor (duplex/MPF) stalled.
160.83
The motor (duplex/MPF) stalled.
150.84
The motor (duplex/MPF) ran too slow.
160.84
The motor (duplex/MPF) ran too slow.
150.85
The motor (duplex/MPF) ran too fast.
150.86
The motor (duplex/MPF) did not run at the correct
timing.
160.86
The motor (duplex/MPF) did not run at the correct
timing.
Action
Yes
No
Step 6
Replace the controller board. See
“Controller board removal” on
page 393
.
Does the problem remain?
Contact the next
level of support.
The problem is
solved.