5028
Blurred print or misaligned color check
Diagnostics and troubleshooting
44
Actions
Yes
No
Step 1
a
From the home screen, touch
Settings
>
Print Quality Pages
.
b
Check the test page.
Is only one color blurred or misaligned?
Go to step 2.
Go to step 3.
Step 2
Perform the color alignment adjustment on the misaligned color.
See
“Color alignment adjust” on page 282
.
Does the problem remain?
Go to step 3.
The problem is
solved.
Step 3
Perform color alignment adjustment on all colors. See
“Color
alignment adjust” on page 282
.
Does the problem remain?
Go to step 4.
The problem is
solved.
Step 4
Perform the Auto alignment service check. See
“Auto alignment
service check” on page 265
.
Does the problem remain?
Go to step 5.
The problem is
solved.
Step 5
a
Open and close the toner door a few times to clean the toner
patch sensors and alignment sensor.
b
Enter the Diagnostics menu, and then navigate to:
Advanced Print Quality Samples
>
Advanced Print Quality
Samples
Does the problem remain?
Go to step 6.
The problem is
solved.
Action
Yes
No
Step 4
If the affected color is cyan, magenta, or yellow, then replace
the developer unit of the affected color.
If the affected color is black, then replace the imaging unit.
Does the problem remain?
Go to step 5.
The problem is
solved.
Step 5
Replace the imaging kit.
Does the problem remain?
Contact the next
level of support.
The problem is
solved.