5028
Missing color check
Diagnostics and troubleshooting
58
Action
Yes
No
Step 1
Make sure that all packing materials of the imaging unit are
removed.
Does the problem remain?
Go to step 2.
The problem is
solved.
Step 2
Make sure that all supplies are properly installed.
Does the problem remain?
Go to step 3.
The problem is
solved.
Step 3
Reinstall the imaging unit and waste toner bottle.
Does the problem remain?
Go to step 4.
The problem is
solved.
Action
Yes
No
Step 11
Check the electrical contacts on the transfer module for damage.
Are the contacts on the belt damaged?
Go to step 12.
Go to step 13.
Step 12
Replace the transfer module. See
“Transfer module removal” on
page 371
.
Does the problem remain?
Go to step 13.
The problem is
solved.
Step 13
Replace the HVPS. See
“HVPS removal” on page 356
.
Does the problem remain?
Contact the next
level of support.
The problem is
solved.