MX-M182 SIMULATIONS 7-30
43 04 Fusing temperature setting 4
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the current display value is increased. For the set value, refer to Table 3.
Every time when [ ] key is pressed, the current display value is decreased. For the set value, refer to Table 3.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Window display Setting item Setting range
1: TMPFIRST JOB initial correction temperature *3 -20 - 20 *1
2: TMPLAST JOB latter-half correction temperature *4 -20 - 20 *2
3: CNTFIRST JOB initial temperature correction number of sheets 0 - 255
4: CNTTYPE1 JOB latter-half temperature correction number of sheets
(Paper size: A3/WLT) 0 - 255
5: CNTTYPE2 JOB latter-half temperature correction number of sheets
(Paper size: A4/LT) 0 - 255
6: CNTTYPE3 JOB latter-half temperature correction number of sheets
(Paper size: except A3/WLT/A4/LT) 0 - 255
*1, *2: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 3.)
*3: Correction temperature from starting a JOB to reaching the JOB initial temperature correction number
of sheets
*4: Correction temperature from the JOB initial temperature correction number of sheets to JOB end
Table 3:
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
Default:
TMPFIRST: 5
TMPLAST: -5
CNTFIRST: 3
CNTTYPE1: 50
CNTTYPE2: 50
CNTTYPE3: 25
43 12 Standby mode fusing fan rotation setting
When this simulation is executed, the currently set code number is displayed.
Select a mode to be changed with the arrow keys and enter a set value with numeric keys.
Enter the mode number to be selected with numeric keys and press [OK] key or [START] key. The set value
is saved in the EEPROM.
Default:
LOW:0
HIGH:1
Main
code
Sub
code
Contents Remark
Sim43-4 FUSER TMP 4
1:TMPFIRST
2:TMPLAST
3:CNTFIRTS
5
-5
3
5
Sim43-4 FUSER TMP 4
4:CNTTYPE1
5:CNTTYPE2
6:CNTTYPE3
50
50
25
50
NO. 012345678
Temperature (°C) -20 -15 -10 -5 0 5 10 15 20
Sim43-12 FAN SPEED
1:LOW
2:HIGH
[ 0-1]
0
1
0
FAN rotation speed
0 : Low speed rotation
1 : High speed rotation
Setting mode
LOW Setting in normal temperature adjustment (190°C or below)
HIGH When the fusing temperature is 190°C or above