Engine soft switch setting
Uncontaminated scan position
search (prevents lines):-
000 = Startup & Job Completion
ON.
001 = Startup only ON.
010 = Job completion only ON.
100 = OFF (Disabled)
Controller soft switch setting:-
Auto clear function before copy
job execution:-
Process mixed original size
printing for duplex mode:-
Paper type simplification
selection:-
Ethernet Speed Auto
negotiation:-
0 = Enabled, 1 = Disabled
0 = 100Base TX, 1 = 10Base T
Ethernet 100/1000 Link Speed:-
0 = 100Base TX, 1 = 1000Base T
Maintenance notification
setting by Printer MIB:-
0 = Enabled, 1 = Disabled
Default display setting for direct
character input:-
0 = Soft keyboard, 1 = External
Display toner remaining status:-
0= Disabled, 1 = Enabled/Display
LCD character display font:-
Continuous print mode for OSA
(job queuing for external
accounting):-
0 = Job Queue Disabled
1 = Job Queue Enabled
Export/Import Filing Data
Document filing data backup
SDRAM read/write test (ICU)
LSU Writing Adjustment/Test
LSU test (Polygon motor & BD signal)
HDD partial read/write check
HDD read/write check (all areas)
Smart (HDD) self diagnostics test (must be
FAT32 formatted)
Smart (HDD) self diagnostics error log
HDD format (excluding system &
operation manual area)
Job completion list deletion (with job log)
Document filing data deletion
Enable/disable auto format (HDD trouble)
HDD format (manual area only)
CCD Operation & Adjustment
Shading correction data display
Shading correction execution (force)
CCD gamma & colour correction auto
adjustment
SIT chart patch density list display
CCD gamma & colour correction reset
Engine test print (B/W mode)
Printer self print test (PCL)
Printer self pint test (PS)
Test print (Sim 46-16 adjustment pattern).
LCD Operation & Adjustment
LCD touch panel adjustment
LCD touch panel adjustment result display
Operation panel key input test