Maintenance
16
SHARP Document Solution Centre
Interval Checklist
500k 1000k 3000k Process Section:
x Replace Developer [MX-900GV]
x
Replace OPC Drum [MX-850GR]
Replace Developer Maintenance Kit [MX-900DK]:-
Doctor cover unit / DV seal.
DV side seal F.
DV side seal R.
DV box filter.
DV toner filter.
Replace Cleaning Blade Kit [MX-900CB]:-
Cleaning blade.
Side seal F.
Side seal R.
Sub blade.
Drum separation pawl x4
Duct sheet.
Relocate Drum Separation Pawl mounting position
Clean Before-Transfer Discharge Lamp.
Clean OPC Drum Surface Potential Sensor
Use Blow Brush or Dry Cloth – DO NOT CLEAN with Vacuum Cleaner
Replace Main Charge Kit [MX-900MK]:-
Charger wire x2.
Screen grid.
Charger cleaner.
Charger cushion.
Cleaner base guide.
x Clean Main Charger Case
x x Replace Main Charger Case [PCASZ0326FCZ1]
x x Replace Process Unit Blade Side Seal Front [PSEL-0992FCZ1] and
Rear [PSEL-0991FCZ1]
Replace Ozone Filter Kit [MX-900FL] :-
Ozone filter
Outlet filter.
x Sim 24-05 Clear Developer Print, Rotation & Day Counter
(only when Developer is replaced)
x Sim 25-02 Toner Concentration Adjustment
(only when Developer is replaced)
Sim 24-04 Clear MAINTENANCE ALL Counter
x Sim 24-04 Clear DRUM CRTG K Counter
(only when OPC Drum is replaced)
Sim 24-04 Clear DRUM BLADE K Counter
(only when Drum Cleaner Blade is replaced)