When the mirroring kit is installed, the two HDD units are named HDD1 (Standard Machine HDD) and HDD2
(Mirroring Kit HDD). The status of the Mirroring Kit is displayed by one of the following UI Icons within the
operation panel:-
Mirroring Kit is installed.
Mirroring Kit / HDD Trouble.
Mirroring Kit / Rebuilding - Copying the whole contents of one HDD to the other HDD.
Troubleshooting:
Use SIM62-20 to check the HDD status, and refer to the following tables to confirm the relation between
the HDD status and possible remedy :-
Status & Trouble when is displayed:-
SIM 62-20
HDD2
OK NONE REBUILDING ERROR TROUBLE
HDD1
OK A A A
NONE A
REBUILDING
ERROR A
TROUBLE A
Status & Trouble when E7-03 error message is displayed:-
SIM 62-20
HDD2
OK NONE REBUILDING ERROR TROUBLE
HDD1
OK B B or C B B B
NONE B or C C C C C
REBUILDING B C F F F
ERROR B C F F F
TROUBLE B C F F D or E
Cont’d