29
E
RS-232C command table
How to read the command table
Command: Command field (See page 28.)
Direction: W When the “Parameter” is set in the parameter field (see page 28), the command functions as described
under “Control/Response Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????” or “
?” in the
parameter field. (See page 28.)
Parameter: Parameter field (See page 28.)
Reply: Response (Returned value)
* : “●” : Indicates a command which can be used in standby state, input signal waiting state or when the
power is on.
“ ” : Indicates a command which can be used in input signal waiting state or when the power is on.
“–” : Indicates a command which can be used when the power is on.
Power control/Input mode selection
Function
Command Direction
Parameter Reply Control/Response contents *
POWER CONTROL POWR W 0
Switches to standby state.
1 Returns from standby state.
R 0 Standby state
1 Normal mode
2 Input signal waiting state
INPUT MODE SELECTION INPS WR 0 Toggle change for input mode.
2 D-SUB
10 HDMI1
11 USB
13 HDMI2
18 HDMI3
PICTURE menu
Function
Command Direction
Parameter Reply Control/Response contents *
BRIGHT VLMP WR 0-50 0-50
-
SIZE (Screen size selection) WIDE WR 1-4 1-4 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM
COLOR MODE BMOD WR 0 0 STD
2 2 VIVID
3 3 sRGB
4 4 HIGH ILLUMINANCE
WHITE BALANCE WHBL WR 0-2 0-2 0:THRU, 1:PRESET, 2:USER
R-CONTRAST CRTR WR 0-255 0-255 “ERR” when WHBL is not set to 2.
G-CONTRAST CRTG WR 0-255 0-255
B-CONTRAST CRTB WR 0-255 0-255
SETUP menu
Function
Command Direction
Parameter Reply Control/Response contents *
DATE/TIME SETTING DATE WR
AABBCCDDEE AABBCCDDEE
AA: Year, BB: Month, CC: Day, DD: Hour, EE: Minute
-
Telnet User name USER WR XXXXXXXX XXXXXXXX 8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The eld can be left blank, but spaces cannot be entered.)
Telnet Password PASS WR XXXXXXXX XXXXXXXX 8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The eld can be left blank, but spaces cannot be entered.)
THERMAL SENSOR SETTING STDR WR 0-3 0-3 0: LANDSCAPE, 1: PORTRAIT, 2: FACE UP, 3: FACE DOWN
Model INF1 R Value
Serial no. SRNO R Value
-
AUTO ASNC W 1 Adjust CLOCK/PHASE/H-POS/V-POS automatically in D-SUB
ALL RESET RSET W 0
Controlling the Monitor with a computer (RS-232C)